Hampton Direct H35-NG1 Installation, Do not overtighten the screw. Recommended to, Before Fig

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 28
Image 28
Fig.4

INSTALLATION

14)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to

grip the wrench by the short side.

15) Verify that if the conversion is from NG to LPG, the screw must be reassembled with the red o-ring visible (Fig. 5).

17) Reverse steps 4) to 2).
4) Attach the DC sparker generator

 

connector to the valve with a screw.

18)Attach clear label "This unit has been converted to LPG" near or on top of the serial # decal.

19)Replace yellow "Natural Gas" label with red "LPG" label.

Installation of the DC Sparker for the H35-1 Units Only:

1)Remove the control panel by unscrewing the 2 screws.

5) Remove the stove’s rear panel by unscrew- ing the two screws.

Red o-ring visible

Fig.5

LPG Configuration

2)First, remove the Piezo Ignition Wire from the Piezo Ignitor. Then remove the Piezo Ignitor from the control panel.

6) Attach the ground wire to the grounding stud.

16) Reassemble the black protection cap (Fig. 6).

3)Plug up the Piezo hole with the plastic bushing.

Before

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors

are appropriate for the gas type.

After