Hampton Direct H35-LP1 General Safety Information, Installation Checklist, This includes

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 7
Image 7
GENERAL SAFETY

INSTALLATION

manufactured home the unit must be bolted down to the fl oor.

4)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

5)This appliance is Listed for Alcove installa- tions, maintain minimumAlcove clearances asfollows, minimumwidthof40"(1016mm), a maximum depth of 36" (914mm), and minimum ceiling height of 64" (1626mm) from fl oor to ceiling.

6)We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have a qualifiedbuildinginspectorreviewyourplans before installation.

GENERAL SAFETY

INFORMATION

1)Theappliance installationmustconformwith local Canadian Electrical Code.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)The appliance should be inspected for shipping damage before use and serv- iced annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding material, etc. It is imperative that control compartments, and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.

5)This appliance must be connected to the specifi ed vent and termination cap to the

outside of the building envelope. Never

vent to another room or inside a building. Make sure that the vent is fi tted as per the instructions starting in the "Exterior Vent Terminal Locations" section.

6)Inspect the venting system annually for blockage and any signs of deterioration.

7)Venting terminals shall not be recessed into a wall or siding.

8)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate your appliance. Refer to the following sections:

a.Clearances to combustibles

b.Locating Your Gas Stove

c.For venting requirements, see "Venting Introduction" to "Venting Arrangements" sections.

2)Install Optional Fan. Refer to the "Optional Fan Installation" section.

3)Set vent restrictors. Refer to the "Vent Re- strictor Position" section.

4)Installventing.Refertothefollowingsections where applicable:

a.Check all venting requirements.

See "Venting Introduction" to "Venting Arrangements" sections.

b.Vertical Termination with Co-linear Flex System

c.DV Stove Horizontal Vent Kit

d.Dura-Vent Termination Kit.

5)Make gas connections. Refer to the "Gas Connection" section

Test the pilot. Must be as per diagram in the "Maintenance Instruction" section.

If converting to Propane, make changes prior see the "Conversion from Natrual Gas to Propane" section.

6)Test Gas Pressure. Refer to the "Gas Pipe Pressure Testing" section.

7)Install standard and optional features. Refer to the following sections where applicable:

a.Log Set Installation

b.Double Door Installation

c.Decorative Door Grill Installation

d.Tile Inset Installation

e.Wall Thermostat

f.Remote Control

8)Final check. Refer to the "Final Check" sec- tion.

Before leaving this unit with the customer, the installer must ensure that the appli- ance is fi ring correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

CLEARANCES TO

COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide.

For example, if the appliance is set as indicated in one of the fi gures but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

Hampton® H35 Direct Vent Freestanding Gas Stove

7

Page 7
Image 7
Hampton Direct H35-LP1 General Safety Information, Installation Checklist, Clearances To Combustibles, This includes