INSTALLATION
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V | H | V + V1 With these options, max. total |
A)1' Min. 3' Max. 2' Min. pipe length is 30 feet with min.
B) | 2' Min. 4' Max. 3' Min. | of 6 feet total vertical and max. |
7 feet total horizontal. |
C)3' Min. 5' Max. 4' Min. Please note min. 1 foot
D)4' Min. 6' Max. 5' Min. between 90o elbows is
E)5' Min. 7' Max. 6' Min. required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Re- strcitor Postion" section.
V1
HV
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option | H + H1 | V |
| With these options, max. total |
A) | 2' Max. | 2' Min. |
| pipe length is 30 feet with min. |
B) | 3' Max. | 3' Min. |
| of 6 feet total vertical and max. |
|
|
|
| 6 feet total horizontal. |
C) | 4' Max. | 4' Min. | ||
|
|
|
| Please note min. 1 foot |
|
|
|
|
D)5' Max. 5' Min. between 90o elbows is
E) 6' Max. 6' Min. required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Restrcitor Postion" section.
V
H
H1
16 | Hampton® H35 Direct Vent Freestanding Gas Stove |