Hampton Direct H35-NG1 Installation, V1 HV, V H H1, Vertical Venting with Two 2 90o Elbows

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 16
Image 16
Vertical Venting with Two (2) 90o Elbows

INSTALLATION

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 With these options, max. total

A)1' Min. 3' Max. 2' Min. pipe length is 30 feet with min.

B)

2' Min. 4' Max. 3' Min.

of 6 feet total vertical and max.

7 feet total horizontal.

C)3' Min. 5' Max. 4' Min. Please note min. 1 foot

D)4' Min. 6' Max. 5' Min. between 90o elbows is

E)5' Min. 7' Max. 6' Min. required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open), refer to the "Vent Re- strcitor Postion" section.

V1

HV

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H + H1

V

 

With these options, max. total

A)

2' Max.

2' Min.

 

pipe length is 30 feet with min.

B)

3' Max.

3' Min.

 

of 6 feet total vertical and max.

 

 

 

 

6 feet total horizontal.

C)

4' Max.

4' Min.

 

 

 

 

Please note min. 1 foot

 

 

 

 

D)5' Max. 5' Min. between 90o elbows is

E) 6' Max. 6' Min. required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open), refer to the "Vent Restrcitor Postion" section.

V

H

H1

16

Hampton® H35 Direct Vent Freestanding Gas Stove

Page 16
Image 16
Hampton Direct H35-NG1, H35-LP1 Installation, V1 HV, V H H1, Vertical Venting with Two 2 90o Elbows, Option, H + H1