INSTALLATION

CATHEDRAL CEILINGS

Round Support (RDS) &

Square Support (SQS)

If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.

1)Situate the chimney in a convenient loca- tion as near as possible to the appliance outlet. Cut and frame a hole in the roof for the support. The sides of this hole must be vertical with 1 1/4" (32mm) clearance.

2)Place the support in the opening. Lower it to the correct height as determined by the table and diagram below.

Slope

"X"

 

 

 

0/12

- 2/12

4"

2/12

- 7/12

5-1/2"

7/12

- 12/12

6-3/4"

12/12

- 24/12

7-1/2"

24/12+

 

12-1/2"

 

 

 

Using a level, make sure the support is vertical. If the support extends above the roof, cut it fl ush with the top of the roof. Nail the support to the frame opening using (8) 3" spiral nails or #8 x 1-1/2" screws.

Note: If you are using a 6" square support you may find it difficult to screw it in place because it is fairly small inside.

Simpson Dura-Vent has provided angle brackets with this support which can be screwed to the outside of the support box and nailed to surrounding framing as required. Use a minimum of four #8 x 1/2" screws per bracket. In some cases these brackets may need to be trimmed (e.g.: to fi t under a fl ashing). Place the Finish Collar around the support and fasten it to the ceiling using the screws provided.

3)Use appropriate roof fl ashing. Place the flashing under the upper shingles and on top of the lower shingles approximately half of the fl ashing should be under the shingles.

4)Assemble the desired lengths of Black Pipe and Elbows necessary to reach from the appliance adapter up through the support box and fl ashing to proper height as per Diagram 12, local codes or the "Exterior Vent Terminal Locations" section. Ensure that all pipe and elbow connections are in their fully twist lock position.

5)Ensure vent is vertical and secure flashing to the roof with roofi ng nails. Slide the storm collar over the pipe section and seal with a mastic.

6)Twist lock the vent cap on to the last sec- tion.

Support Extensions - Round

(RDSE)

or Square (SQSE)

Steep pitched cathedral ceilings may require the use of a support extension. This piece fi ts down inside the support and can be adjusted to increase the support's length by up to 22" (559mm). The extension is attached to the sup- port using the eight metal screws provided. Be sure there is at least a 2" (51mm) overlap where the extension joins the support.

HIGH ELEVATION

This unit is approved in Canada for altitude to 4500 ft. (CAN/CGA-2.17-M91). For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1.

GAS CONNECTION

The gas connection is a 3/8" NPT90o elbow.The gas line can be rigid pipe or to make installation easier, use a listed flexible connector and/or cop- per tubing if allowed by local codes. Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation codes.

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only approved fi ttings.Always provide a union so that gas lines can be easily disconnected for burner and/orvalveservicing.Flarenutsforcopperlines and fl ex connectors are usually considered to meet this requirement.

IMPORTANT: ALWAYS CHECK FOR GAS LEAKS WITH A SOAP AND WATER SOLUTION OR GAS LEAK DETECTOR. DO NOT USE OPEN FLAME FOR LEAK TESTING.

Note: Prior to any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance must be disconnected from the piping system. If test pres- sures equal to or less than 1/2 psig are used then this appliance must be isolated from the piping system by closing its individual manual shut-off valve during the testing.

SYSTEM DATA - H35

For 0 to 4500 feet altitude

Natural Gas

 

 

Max. Input Rating

36,000 Btu/h

Min. Input Rating

18,000 Btu/h

Orifi ce Size

#33 DMS

Convertible to:

 

 

Max. Input Rating

30,000 Btu/h

Min. Input Rating

14,300 Btu/h

Orifi ce Size

#37 DMS

 

 

 

Propane

 

 

Max. Input Rating

34,000 Btu/h

Min. Input Rating

17,500 Btu/h

Orifi ce Size

#51 DMS

Convertible to:

 

 

Max. Input Rating

28,500 Btu/h

Min. Input Rating

15,000 Btu/h

Orifi ce Size

#52 DMS

 

 

 

Supply Pressure

 

 

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

 

 

 

Manifold Pressure

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

Hampton® H35 Direct Vent Freestanding Gas Stove

25

Page 25
Image 25
Hampton Direct H35-LP1, H35-NG1 installation manual Cathedral Ceilings, High Elevation, GAS Connection

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.