INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
WALL THERMOSTAT
A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:
Note: Preferable if the thermostat is installed on an interior wall.
Hampton® offers an optional programmable thermostat but any
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
Wire Size | Max. Length | |
14 GA. | 50 | Ft. |
16 GA. | 32 | Ft. |
18 GA. | 20 | Ft. |
20 GA. | 12 | Ft. |
22 GA. | 9 | Ft. |
REMOTE CONTROL
Use the Hampton® Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
Hampton® H35 Direct Vent Freestanding Gas Stove | 37 |