Hampton Direct H35-LP1 Installation, Venting Arrangements, Vertical Terminations Systems for

Models: H35-NG1 H35-LP1

1 48
Download 48 pages 46.67 Kb
Page 13
Image 13
Remove all 4 screws

INSTALLATION

ROTATING 45O ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS

1)Removeall4screwsthatsecure the elbow to the unit using a 1/4" magnetic nut driver.

2)Rotate the elbow 180o

3)Secure the elbow by securing it with the 4 screws.

Remove all 4 screws

and washers

 

VENTING ARRANGEMENTS

Horizontal Terminations for All

Vertical Terminations Systems for

Venting Systems

Residential Manufactured and Mobile Homes

The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).

The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows.

If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combus- tibles.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Propane and Natural Gas:

Residential, Manufactured andOffset to Vertical Terminations Mobile Homes Installations

The venting arrangements diagrammed below, have a min. of 75% (fl ue loss) efficiency with Fan Off, as required for manufactured homes. (Actual efficiency may be as high as 85%)

May be installed in Manufactured (Mobile)
Homes after fi rst sale.

NOTE: See "Vent Restrictor Position" section for installation instructions for the Vent Restrictor Position.

Hampton® H35 Direct Vent Freestanding Gas Stove

13

Page 13
Image 13
Hampton Direct H35-LP1, H35-NG1 Installation, Venting Arrangements, Vertical Terminations Systems for, Venting Systems