INSTALLATION
VENTING | INSTALLATION | VENT RESTRICTOR |
INTRODUCTION | PRECAUTIONS | POSITION |
The Horizontal Termination Kit and the Simpson
These units use the "balanced fl ue" technology
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.
Thelocationoftheterminationcapmustconform totherequirementsinthe"ExteriorVentTerminal Locations" section.
These venting systems are engineered products that have been designed and tested for use with the
1)Installation of any damaged Direct Vent component
2)Unauthorized modification of the Direct Vent System
3)Installation of any component part not manu- factured or approved by Simpson
4)Installation other than as instructed by Simp- son
Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.
Be sure to check the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section and in your local building codes.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or
Vent restriction is required for certain venting installations, see the diagrams in "Venting Arrangment" section to determine if they are required for your installation.
To set the Vent restriction as indicated in the diagrams in the "VentingArrangement" section, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.
Horizontal Termination:
Vent Restrictor setting at 36,000 Btu/h
Vertical Termination:
Vent Restrictor setting at 36,000 Btu/h
SAFETY PRECAUTIONS
FOR THE INSTALLER
1)Wear gloves and safety glasses for protec- tion.
2)Exercise extreme caution when using lad- ders or on roof tops.
3)Be aware of electrical wiring locations in walls and ceilings.
Hampton® H35 Direct Vent Freestanding Gas Stove | 9 |