Meyer Sound galileo 616 Copy, Paste, Load, Save, and Reset Control Values, Delay Units and Ranges

Models: galileo 616

1 180
Download 180 pages 17.04 Kb
Page 77
Image 77

COMPASS USER GUIDE

Delay Units and Ranges

Delay values are correlated, allowing automatic conversion from one measurement unit to another when changing the unit measure. Delay units and value ranges are as follows:

Table 3.1. Delay Unit Ranges

 

Unit

Range

Milliseconds (ms)

0.00−2000.00 ms

Meters (m)

0.00−686.4 m

Feet (ft)

0.00−2 251.97 ft

Frames (24 fps)

0.00−02:00.00

Frames (25 fps)

0.00−02:00.00

Frames (30 fps)

0.00−02:00.00

Samples (96 kHz)

0.00−192 000

Setting Input Channel Delay

1.Select the [Galileo Unit] > Input Processing > Channel Settings page.

2.Select the desired units measure (milliseconds, feet, meters, frames, or samples).

3.Set the Delay value.

Setting Output Channel Delay

1.Select the [Galileo Unit] > Output Processing > Channel Settings page.

2.Select the desired units measure (milliseconds, feet, meters, frames, or samples).

3.Set the Delay value.

Copy, Paste, Load, Save, and Reset Control Values

Many controls in Compass support the use of right-click to copy, paste, save, load, and reset control values or the values of a set of controls.

The Paste, Copy, Save, Load, and Reset actions are described as “Copy/Reset” in the following task descriptions (pasting and loading implies the value was copied in the first place.)

59

Page 77
Image 77
Meyer Sound galileo 616 operating instructions Copy, Paste, Load, Save, and Reset Control Values, Delay Units and Ranges