Enable Linking AcrossSelected Galileos
Replicates these settings acrossall selected Galileos when Global Galileo Select-Linking
Mode (p. 78) is enabled.
Input Channel Types:
A Galileo can accept up to six analog inputs or threedigital (AES/EBU) inputs. These inputs
arenamed in stereo pairs (A/B; C/D; E/F).
Analog / AES
Configuresthe input for analog input or AES digital input.
The image displaying the threeXLR input pairs on the back of the Galileo indicates which
connectorsare enabled. When using AES/EBU input, the bottom connector is not available
for use.
Input VoltageRange:
Enabled for analog inputs only.
+26 dBu / +20 dBu
+26 dBu is standardsignal level for analog input.
+20dBu may be useful as a studio mode. This setting may cause clipping or increase noise
levels. Use with caution!
Set all to +26 dBu / Set all to +20 dBu
Providesa shortcut to set all input voltages to the same range.
Output VoltageRange:
+26 dBu / +20 dBu
+26 dBu is standardsignal level for analog output.
+20dBu may be useful as a studio mode. This setting may cause clipping or increase noise
levels. Use with caution!
Set all to +26 dBu / Set all to +20 dBu
Providesa shortcut to set all output voltages to the same range.
104