Marantz DV7110 manual RS-232C System control

Models: DV7110

1 111
Download 111 pages 30.47 Kb
Page 51
Image 51

RS-232C System control

This DVD player can be controlled by a PC. Connect the player and a serial port on the PC with a 9-pin RS-232C straight cable. To control this DVD player by a PC, set the RS- 232C switch on the rear panel to RS-232C.

RS-232C Pin assignments

 

 

Pin No.

Signal

1

5

1

Not connected

 

 

2

RXD

 

 

3

TXD

6

9

4

Not connected

5

GND

 

 

 

 

6

Not connected

 

 

7

RTS

 

 

8

CTS

 

 

9

Not connected

Communication conditions

Configure the serial port of the PC as shown below.

Baud Rate

9600bps

Data Bits

8bit

Parity

None

Stop bit

1bit

Handshaking

RTS/CTS

SYSTEM (HOST) ´ DV7110

RTS

 

 

 

CTS

 

 

CTS

 

 

 

RTS

 

 

 

TXD

 

 

 

RXD

 

 

 

RXD

 

 

 

TXD

1.The host requests data by setting RTS to L.

2.Upon data request by CTS, the slave responds by setting RTS to H if not busy.

3.The host checks if CTS is H and starts data output on TXD.

4.When data output finishes, the host sets RTS to H.

5.The slave checks if CTS is H and sets RTS to L.

Basic format

Command format

Header

Addr COMMAND

Return

@

1

0Dh

Reponse code format

 

 

 

Normal response

Error response

 

 

 

 

 

 

OK

 

 

ERR

 

 

06h

 

 

15h

 

ENGLISH

System commands

There are 3 types of commands. Normal command is to request operation from PC to DVD player. Request command is to request player status and Status command is to let the PC know the change of DVD player status.

Upon reception of a command, DVD player will return either OK, ERROR or Status.

ASCII code is used for data and letters are case sensitive. The start character and the end character are added as shown below for sending command and returning status. The DVD player’s own ID code follows the start character. This ID code is 1.

Start Character

:

’@’

End Character

:

0Dh

Command Sample

“1?A”, 0Dh

 

(ID=1 Request Power Status)

FeedbOK Sample

“1A1“, 0Dh

 

(ID=1 Power Status = On)

The following codes are used for OK and ERROR.

OK (data receive successful) : 06h

ERROR (data receive error) : 15h

The receiving side ignores data received prior to ’@’. If 0Dh is received without receiving ’@’, ERROR(data receive error) will be returned.

For numeric data, ASCII coded hexadecimal number is used.

(example) For a decimal number 26

'1', 'A' 0x31, 0x41

Hand shake flow chart

Normak command and

Request command

 

 

Request command

 

 

 

 

 

DV7110

PC

DV7110

PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

ADDITIONAL

 

 

 

 

 

 

 

 

 

Command

 

 

 

 

 

 

 

Status

 

 

OK

 

 

 

Command

 

 

 

 

 

Request

 

OK

INFORMATION

 

 

 

Command

 

 

 

 

 

 

 

 

Answer

 

 

 

 

 

 

data

 

 

 

 

 

 

 

 

 

 

 

 

 

51

Page 51
Image 51