15. GREEN Gain Data

Function

The external control equipment changes the GREEN Gain Data of the plasma monitor. Note that this command can be accepted only when PRO is selected from COLOR TEMP.

Transmission Data

DFH 80H 60H 7FH 04H

DATA00 to DATA03 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

GREEN Gain Flag

02H

DATA02:

GREEN Gain 1 (Bias)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

DATA03:

GREEN Gain2 (Drive)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

ACK

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

GREEN Gain Flag

02H

16. BLUE Gain Data

Function

The external control equipment changes the BLUE Gain Data of the plasma monitor. Note that this command can be accepted only when PRO is selected from COLOR TEMP.

Transmission Data

DFH 80H 60H 7FH 04H

DATA00 to DATA03 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BLUE Gain Flag

03H

DATA02:

BLUE Gain1(Bias)

D8H:-40

 

 

 

 

 

 

FFH:-1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

DATA03:

BLUE Gain2(Drive)

D8H: -40

 

 

 

 

 

 

FFH:-1

 

 

00H: 0

 

 

 

 

 

 

IEH:+30

ACK

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BLUE Gain Flag

03H

17. NR MODE Set

Function

The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.

Transmission Data

DFH 80H 60H C0H 01H DATA00 CKS

DATA00: 01H: NR OFF 02H: NR-1

03H: NR-2

04H: NR-3

ACK

7FH 60H 80H C0H 01H DATA00 CKS

DATA00: 01H: NR OFF 02H: NR-1

03H: NR-2

04H: NR-3

18. BASS Gain Data

Function

The external control equipment changes the BASS gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BASS Gain Flag

03H

DATA02:

BASS Gain

F3H: -13

 

 

 

 

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

 

 

 

 

0DH: +13

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BASS Gain Flag

03H

19. TREBLE Gain Data

Function

The external control equipment changes the TREBLE gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

 

DATA00:

USER PICTURE Gain Flag

05H

 

DATA01:

TREBLE Gain Flag

04H

 

DATA02:

TREBLE Gain

F3H: -13

 

 

 

 

 

 

 

 

FFH: -01

 

 

 

00H: 0

 

 

 

01H: +01

 

 

 

 

 

 

 

 

0DH: +13

 

ACK

 

 

 

 

 

 

 

 

 

7FH

60H 80H 7FH 02H

DATA00 DATA01 CKS

45

DATA00:

USER PICTURE Gain Flag

05H

 

DATA01:

TREBLE Gain Flag

04H

Page 52