36. INVERSE Set

36. INVERSE Set

Function

The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasma monitor.

Transmission Data

DFH

80H

60H

C7H

03H DATA00 DATA01 DATA02 CKS

DATA00 :

INVERSE/WHITE

00H: No operation

 

 

 

 

01H: ON(INVERSE)

 

 

 

 

02H: OFF

 

 

 

 

03H: WHITE

DATA01 : WORKING TIME

00H: ON

 

 

 

 

01H: 03M (minutes)

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

DATA02 :

WAITING TIME

01H: 03M (minutes)

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

ACK

 

 

 

 

 

 

 

 

 

 

 

3FH

60H

80H

C7H

00H CKS

 

 

 

 

 

 

NOTE: The WORKING TIME and the WAITING TIME can be set in units of 3 minutes.

Example: 03H=9 minutes

1EH=1 hour and 30 minutes

37. SCREEN WIPER Set

Function

The external control equipment sets the SCREEN WIPER of the plasma monitor.

Transmission Data

DFH

80H

60H

C8H

04H

 

DATA00 to

DATA03 CKS

DATA00 : SCREEN WIPER

 

00H: No operation

 

 

 

 

 

01H: ON

 

 

 

 

 

 

02H: OFF

 

DATA01 : WORKING TIME

 

00H: ON

 

 

 

 

 

 

01H: 03M (minutes)

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

DATA02 : WAITING TIME

 

01H: 03M (minutes)

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

DATA03 : SPEED

 

 

01H: 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05H: 5

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3FH

60H

80H

C8H

00H

 

CKS

 

 

 

 

 

 

 

 

 

NOTE: The WORKING TIME and the WAITING TIME can be set in units of 3 minutes.

Example: 03H=9 minutes

1EH=1 hour and 30 minutes

38. RESET

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH 80H 60H 54H 00H CKS

ACK

3FH 60H 80H 54H 00H CKS

39. Audio Select Set

Function

The external control equipment sets combinations of audio and video inputs for the plasma monitor.

Transmission Data

DFH 80H 60H 70H 02H

DATA00 DATA01 CKS

DATA00:

AUDIO INPUT

01H: AUDIO 1

 

 

02H: AUDIO 2

 

 

03H: AUDIO 3

DATA01:

VISUAL INPUT

01H: Video 1

 

 

02H: Video 2

 

 

03H: Video 3

05H:HD (HD1 or DTV or DTV1) 06H: HD2 (DTV2)

07H: RGB 1/ PC 1

08H: RGB 2/ PC 2

0CH: RGB 3/ PC 3

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 70H 00H CKS

*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.

Example:

The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.

49