50. Audio Select Request

Function

The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.

Transmission Data

1FH 80H 60H 6FH 00H CKS

ACK

The plasma monitor returns the following ACK:

7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

AUDIO 1

 

 

01H – 0CH: VISUAL INPUT DATA

DATA01:

AUDIO 2

 

 

01H – 0CH: VISUAL INPUT DATA

DATA02:

AUDIO 3

 

 

01H – 0CH: VISUAL INPUT DATA

 

VISUAL INPUT DATA

 

01H:

Video 1

 

02H:

Video 2

 

03H:

Video 3

 

05H:

HD (HD1 or DTV or DTV 1)

 

06H:

HD2 (DTV2)

 

07H:

RGB 1 /PC 1

 

08H:

RGB 2 /PC 2

 

0CH:

RGB 3 /PC 3

51. Failure Mode Request

Function

The external control equipment inquires the detection of failures of the plasma monitor.

Transmission Data

1FH 80H 60H 3FH 00H CKS

ACK

The plasma monitor returns the following ACK:

7FH 60H 80H 3FH 02H DATA00 DATA01 CKS

DATA00: FAILURE MODE 1

Bit 0 : PDP MODULE

0:Abnormal

1:Normal

Bit 1 : 1: fixed (backup)

Bit 2 : TEMPERATURE

0:Abnormal

1:Normal

Bit 3 : FAN

0:Abnormal

1:Normal

Bit 4 : 1: fixed (backup)

Bit 5 : 1: fixed (backup)

Bit 6 : 1: fixed (backup)

Bit 7 : 1: fixed (backup)

DATA01: FAILURE MODE 2

Bit 0–7 : 1: fixed (backup)

52. MODEL NAME Request

Function

The external control equipment inquires the product code of the plasma monitor.

Transmission Data

1FH 80H 60H 17H 00H CKS

ACK

The plasma monitor returns the following ACK:

7FH 60H 80H 17H 0CH DATA00 to

DATA11 CKS

DATA00 : 1st character of the product code

DATA01 : 2nd character of the product code

DATA11 : 12th character of the product code

NOTE:

Received data (Hex)

Corresponding character

00H

0

01H

1

 

 

 

 

08H

8

09H

9

10H

A

11H

B

12H

C

 

 

 

 

28H

Y

29H

Z

80H

- (Hyphen)

96H

(Blank)

If there are fewer than 12 characters in the product code, product code would be padded right with blanks.

Example: If the product code of your plasma monitor is “PD5020D”, the returned codes would be as follows.

DATA00: 1FH

DATA01: 13H

DATA02: 05H

DATA03: 00H

DATA04: 02H

DATA05: 00H

DATA06: 13H

DATA07: 96H

DATA08: 96H

DATA09: 96H

DATA10: 96H

DATA11: 96H

54

Page 61
Image 61
Marantz PD5020D manual Audio Select Request, Failure Mode Request, Model Name Request