30. OSM ADJ. Gain Data

Function

The external control equipment sets the position of the OSM menu of the plasma monitor.

Transmission Data

DFH

80H

60H

1AH

02H

DATA00 DATA01 CKS

DATA00:

OSM ADJ. Gain Flag

02H

DATA01:

01H: 1

 

 

 

 

 

 

 

 

 

 

09H: 9

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

1AH

01H

DATA00 CKS

DATA00:

OSM ADJ. Gain Flag

02H

31. POWER MGT Select

Function

The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.

Transmission Data

DFH

80H

60H

1AH

02H

DATA00 DATA01 CKS

DATA00:

POWER MGT Select

 

03H

DATA01:

01H: ON

 

 

 

 

02H: OFF

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

1AH

02H

DATA00 DATA01 CKS

DATA00:

POWER MGT Select

 

03H

DATA01:

01H: ON

 

 

 

 

02H: OFF

 

 

 

32. GRAY LEVEL Set

Function

The external control equipment sets the GRAY LEVEL of the plasma monitor.

Transmission Data

DFH

80H

60H

C6H 01H

DATA00 CKS

DATA00:

GRAY LEVEL

00H: 0

 

 

 

 

 

 

 

 

 

 

0FH: 15

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

C6H 01H

DATA00 CKS

DATA00:

GRAY LEVEL

00H: 0

 

 

 

 

 

 

 

 

 

 

0FH: 15

33. CINEMA MODE Set

Function

The external control equipment switches on or off the CINEMA MODE of the plasma monitor.

Transmission Data

DFH

80H

60H

C1H 01H

DATA00 CKS

DATA00:

CINEMA MODE Set

01H: ON

 

 

 

 

02H: OFF

ACK

 

 

 

 

 

 

 

 

 

7FH

60H

80H

C1H 01H

DATA00 CKS

DATA00:

CINEMA MODE Set

01H: ON

 

 

 

 

02H: OFF

34. RGB3 ADJ. Select

Function

The external control equipment sets the RGB3 ADJUST of the plasma monitor.

Transmission Data

 

 

 

DFH

80H

60H

1AH

02H

DATA00 DATA01 CKS

DATA00:

RGB3 ADJ. Select

 

06H

DATA01:

01H: 1

 

 

 

 

02H: 2

 

 

 

 

03H: 3

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

1AH

02H

DATA00 DATA01 CKS

DATA00:

RGB3 ADJ. Select

 

06H

DATA01:

01H: 1

 

 

 

 

02H: 2

 

 

 

 

03H: 3

 

 

 

35. LONG LIFE Set

Function

The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) of the plasma monitor.

Transmission Data

 

DFH 80H 60H 6BH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

PLE

01H: AUTO

 

 

02H: LOCK

DATA01:

INVERSE

01H: ON

 

 

02H: OFF

 

 

03H: WHITE

DATA02:

ORBITER (PICTURE SHIFT)

01H: ON

 

 

02H: OFF

ACK

The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness):

3FH 60H 80H 6BH 00H CKS

48

Page 55
Image 55
Marantz PD5020D OSM ADJ. Gain Data, Power MGT Select, Gray Level Set, Cinema Mode Set, RGB3 ADJ. Select, Long Life Set