Marantz PD5020D manual BALANCE Gain Data, 23. H. POSITION Gain Data, SCREEN MODE Select

Models: PD5020D

1 68
Download 68 pages 46.11 Kb
Page 53
Image 53
20. BALANCE Gain Data

20. BALANCE Gain Data

Function

The external control equipment changes the BALANCE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BALANCE Gain Flag

02H

DATA02:

BALANCE Gain

EAH: -22

 

 

 

 

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

 

 

 

 

16H: +22

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BALANCE Gain Flag

02H

23. H. POSITION Gain Data

Function

The external control equipment changes the H. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H. POSITION Gain Flag

02H

DATA02:

H. POSITION Gain

80H: -128

 

 

 

 

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

 

 

 

 

7FH: +127

ACK

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H. POSITION Gain Flag

02H

21. SCREEN MODE Select

Function

The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH 80H 60H 51H 01H DATA00 CKS

DATA00: 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: FULL

06H: TRUE (REAL)

ACK

7FH 60H 80H 51H 01H DATA00 CKS

DATA00: 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: FULL

06H: TRUE (REAL)

22. V. POSITION Gain Data

Function

The external control equipment changes the V. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

 

DATA00:

USER PICTURE Gain Flag

03H

 

DATA01:

V. POSITION Gain Flag

01H

 

DATA02:

V. POSITION Gain

C0H: -64

 

 

 

 

 

 

 

 

FFH: -01

 

 

 

00H: 0

 

 

 

01H: +01

 

 

 

 

 

 

 

 

40H: +64

 

ACK

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

 

DATA00:

USER PICTURE Gain Flag

03H

46

DATA01:

V. POSITION Gain Flag

01H

 

24. V-HEIGHT Gain Data

Function

The external control equipment changes the V-HEIGHT gain data of the plasma monitor.

Transmission Data

DFH 80H

60H

7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

V-HEIGHT Gain Flag

07H

DATA02:

V-HEIGHT Gain

00H: 0

 

 

 

 

 

 

 

 

 

 

40H: +64

ACK

 

 

 

 

 

 

 

 

 

7FH 60H

80H

7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

V-HEIGHT Gain Flag

07H

25. H-WIDTH Gain Data

Function

The external control equipment changes the H-WIDTH gain data of the plasma monitor.

Transmission Data

DFH 80H

60H

7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H-WIDTH Gain Flag

08H

DATA02:

H-WIDTH Gain

00H: 0

 

 

 

 

 

 

 

 

 

 

40H: +64

ACK

 

 

 

 

 

 

 

 

 

 

7FH 60H

80H

7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H-WIDTH Gain Flag

08H

Page 53
Image 53
Marantz PD5020D manual BALANCE Gain Data, 23. H. POSITION Gain Data, SCREEN MODE Select, 22. V. POSITION Gain Data