TROUBLESHOOTING

TROUBLESHOOTING

In case of trouble, check the following before calling for service:

1.Are the connections made properly ?

2.Are you operating the unit properly following the user’s guide ?

3.Are the power amplifiers and speaker working properly ?

If the unit does not operate properly, check items shown in the following table.

If your trouble cannot be recovered with the remedy actions listed in the following table, malfunction of the internal circuitry is suspected; immediately unplug the power cable and contact your dealer, nearest Marantz authorized dealer or the Marantz Service Center in your country.

SYMPTOM

CAUSE

REMEDY

 

 

 

ZR6001 cannot be turned up.

The power plug is not connected.

Connect the power plug to the outlet.

 

 

 

No sound and picture are

Mute is on.

Cancel mute using the remote control unit.

output even when power is on.

 

 

The input cable is not connected correctly.

See the connection diagram and connect the

 

 

 

cables correctly.

 

 

 

 

The master volume control is turned all

Adjust the master volume.

 

the way down.

 

 

 

 

 

The function selector position is wrong.

Select correct position.

 

 

 

No speaker output.

The headphones are connected to the

Disconnect the headphones. (Speakers will not

 

headphone jack.

output sound when headphones are connected.)

 

 

 

Incorrect Audio or Video for

Input cable connected incorrectly.

Connect the cable correctly by referring to the

selected source.

 

connection diagram.

 

 

 

Incorrect Audio from a channel.

Speaker cable connected incorrectly.

Connect the cable correctly by referring to the

 

 

connection diagram.

 

 

 

No Audio output from the

The center speaker cable connection is

Connect the cable correctly.

center channel speaker.

incomplete.

 

 

 

 

 

STEREO has been selected for Surround

When STEREO is selected for Surround mode, no

 

mode.

sound will be output from the center speaker. Set

 

 

another Surround mode.

 

Center = NONE has been selected in

Make the correct setting.

 

SETUP mode.

 

 

 

 

No Audio output from the

The surround speaker cable connection

Connect the cable correctly.

surround speakers.

is incomplete.

 

 

 

 

 

STEREO has been selected for Surround

When STEREO has been selected for Surround

 

mode.

mode, no sound will be output from the surround

 

 

speaker. Set another Surround mode.

 

 

 

 

Surround = NONE has been selected in

Make the correct setting.

 

SETUP mode.

 

 

 

 

No Audio output from the

The surround back speaker cable

Connect the cable correctly.

surround back speakers.

connection is incomplete.

 

 

Surround mode is not EX/ES mode.

Set surround mode EX/ES.

 

 

 

 

Surround back = NONE has been

Make the correct setting.

 

selected in SPEAKERS SIZE SETUP

 

 

 

 

Can not select EX/ES mode.

Surround center= NONE has been

Make the correct setting.

 

selected in SPEAKERS SIZE SETUP

 

 

 

 

 

Input signal is incompatible.

Use 5.1channel source.

 

 

 

SYMPTOM

CAUSE

REMEDY

 

 

 

Can not select Pro Logic IIx

Input signal is incompatible.

Use 2 channel Dolby Digital input signal, PCM input

mode.

 

signal or analog input signal.

 

 

 

Can not select Neo:6 mode.

Input signal is incompatible.

Use 2 channel Dolby Digital input signal, PCM input

 

 

signal or analog input signal.

 

 

 

Can not select CSII mode.

Input signal is incompatible.

Use 2 channel Dolby Digital input signal, PCM input

 

 

signal or analog input signal.

 

 

 

No output to Sub Woofer Out.

Sub-woofer = NONE has been selected

Select Sub-woofer = YES.

 

in SETUP mode.

 

 

 

 

Noise is produced during DTS-

Analog has been selected for input.

Be sure to perform digital connection, select digital

encoded CD or laser disc play.

 

input, then play.

 

 

 

A specific channel does not

Nothing recorded on source.

Check the encoded channel on the source side.

produce output.

 

 

 

 

 

FM or AM reception fails.

Antenna connection is incomplete.

Correctly connect the indoor FM and AM antennas

 

 

to FM and AM antenna outlets.

 

 

 

Noise is heard during AM

Reception is affected by other electrical

Try changing location where the AM indoor

reception.

fields.

antenna is set up.

Noise is heard during FM

The radio waves from the broadcasting

Install an FM outdoor antenna.

reception.

station are weak.

 

 

 

 

Cannot get programmed

Preset data has been erased.

Disconnecting power plug for long periods of time

station when the PRESET

 

will erase preset data. If that happens, input the

button is pressed.

 

preset data again.

 

 

 

Control with the remote

Batteries are consumed.

Replace all the batteries with new ones.

control unit fails.

 

 

Remote controller’s function - key

Select different position from which equipment will

 

 

setting is wrong.

be controlled.

 

 

 

 

The distance between this ZR6001 and

Move closer to this ZR6001.

 

the remote commander is too far.

 

 

 

 

 

Something is blocking ZR6001 and the

Remove offending object.

 

remote commander.

 

 

 

 

Nothing is heard over PLC

The PLC is wrongly set.

Correctly set the PLC as explained in “MULTI PLC

connection.

 

SETUP” on page 24.

 

 

You can check whether or not the ZC4001 is

 

 

securely connected to the ZR6001 via the PLC

 

 

status display area of the ZC4001.

 

 

 

 

The source (Marantz product) is not

Marantz products connect over an RC-5 bus.

 

correctly connected to the ZR6001.

Correctly connect the source as explained in

 

 

“CONNECTING TO THE RC-5” on page 17.

 

 

 

 

The source (other brand product) is not

Other brand sources are controlled by remote

 

correctly connected to the ZR6001.

control signals sent from an emitter connected to

 

 

the IR EMITTER OUT terminals of the ZR6001 to

 

 

the IR sensor of the source unit.

 

 

Operation requires you to set the brand code or use

 

 

the IR code learning feature.

 

 

Correctly connect the source as explained in

 

 

“CONNECTING AN IR EMITTER” on page 13.

 

 

 

 

Another device is generating a high

Turn off the device that is causing the noise or

 

level of noise on the power line.

move it farther away from the ZR6001 and ZC4001.

 

 

 

Note:

After “PROTECT” appears on the unit’s display, the standby indicator may start flashing. If it does, there is a problem in the unit or the connection. If this problem reoccurs even when power is activated from the remote control unit, call for servicing.

ENGLISH