Figure 1 - Graph of Transducer Accuracy vs. Tank Depth

FPM100 User’s Manual

Figure 1 - Graph of Transducer Accuracy vs. Tank Depth

The pressure transducer you select must have sufficient range to measure the full height of the liquid column of a full tank. The table in Figure 2 below shows the maximum depth that can be sensed by each pressure transducer type. This table assumes that water level is being measured. The maximum depth of diesel fuel can that can be measured varies from these figures slightly depending on the density of the diesel fuel.

Transducer

Maximum tank depth

 

 

PT-0-3PSI-01 (0-3 PSI)

83.04” (2.11m)

PT-0-5PSI-01 (0-5 PSI)

138.4” (3.52m)

Figure 2 - Pressure Transducer Selection Chart for Tank Level Applications

2 Installation

2.1 Unpacking the Box

When unpacking the box containing the Maretron FPM100, you should find the following items:

1 – FPM100 Fluid Pressure Monitor

1 – Parts Bag containing 4 Stainless Steel Mounting Screws

1 – FPM100 User’s Manual

1 – Warranty Registration Card

If any of these items are missing or damaged, please contact Maretron.