Electrical

FPM100 User’s Manual

Electrical

Parameter

Value

Operating Voltage

9 to 32 Volts

Power Consumption

400mA

Load Equivalence Number (LEN)

8

Reverse Battery Protection

Yes

Load Dump Protection

Yes

Comment

DC Voltage

Maximum Current Drain

NMEA 2000® Spec. (1LEN = 50mA) Indefinitely

Energy Rated per SAE J1113

Mechanical

Parameter

Value

Size

3.50” x 4.20” x 2.03”

 

(88.9mm x 106.7mm x 51.6mm)

Weight

13 oz. (368.5 g)

Comment

Including Flanges for Mounting

Environmental

Parameter

IEC 60945 Classification

Degree of Protection

Operating Temperature

Storage Temperature

Relative Humidity

Vibration

Solar Radiation

Corrosion (Salt Mist)

Electromagnetic Emission

Electromagnetic Immunity

Safety Precautions

Value

Exposed

IP64

-25°C to 55°C -40°C to 70°C

93%RH @40° per IEC60945-8.2

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Conducted and Radiated Emission per IEC 60945-9

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

7 Technical Support

If you require technical support for Maretron products, you can reach us in any of the following ways:

Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

support@maretron.com

World Wide Web:

http://www.maretron.com

Mail:

Maretron, LLP

 

Attn: Technical Support

 

9014 N. 23rd Ave Suite 10

 

Phoenix, AZ 85021 USA

Page 16

Revision 1.3

Page 20
Image 20
Maretron user manual Technical Support, Electrical, Mechanical, Environmental, FPM100 User’s Manual, Page, Revision