6. TROUBLESHOOTING
6-1. Error Code Summary
wWARNING : When you check the Resistance values, be sure to turn off the power. And wait for the
|
| Error Display |
|
| ||
| Error Detection |
|
| Error Generation Factors | Remark | |
NO | Freezer | Ref. | ||||
Category | ||||||
| Temperature | Temperature |
|
| ||
|
|
|
| |||
|
|
|
|
|
| |
1 | Normality |
|
| None | Normal operation of Display | |
|
|
|
|
| ||
|
|
|
|
|
| |
2 | Freezer Sensor | Er | FS | Short or Disconnection |
| |
Error | of Freezer Sensor |
| ||||
|
|
|
|
|
| |
3 | Refrigerator | Er | rS | Short or Disconnection |
| |
Sensor Error | of Refrigerator Sensor | Check each sensor and its | ||||
|
|
| ||||
|
|
|
|
| connector. | |
4 | Defrosting | Er | dS | Short or Disconnection | ||
| ||||||
Sensor Error | of Defrosting Sensor |
| ||||
|
|
|
|
|
| |
5 | Icing Sensor | Er | IS | Short or Disconnection |
| |
of Icing Sensor |
| |||||
Error |
| |||||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
| Even though it is passed |
| |
|
|
|
| 1 hour since then | Temperature Fuse | |
6 | Poor Defrosting | Er | dH | Defrosting , if Defrosting | Disconnection, Heater | |
sensor is not over 8°C, it | disconnection, DRAIN Jam, | |||||
|
|
|
| |||
|
|
|
| is caused | Poor Relay for Heater | |
|
|
|
|
|
| |
|
|
|
| It is caused when | Poor BLDC Motor | |
| Abnormality of |
|
| feedback signal isn’ t | connection, DRIVE IC, and | |
7 | BLDC FAN Motor | Er | IF | over 115 | TR Tx/Rx between icemaker | |
| for Ice Making |
|
| seconds during BLDC | and main board. | |
|
|
|
| FAN motor operating |
| |
|
|
|
|
|
| |
|
|
|
| It is caused when | Poor BLDC Motor | |
| Abnormality of |
|
| feedback | ||
|
|
| connection, DRIVE IC, and | |||
8 |
|
| signal isn’ t over 115 | |||
BLDC FAN Motor | Er | FF | TR Tx/Rx between icemaker | |||
seconds during BLDC | ||||||
| for Freezer |
|
| and main board. | ||
|
|
| FAN motor operating | |||
|
|
|
|
| ||
|
|
|
|
|
| |
| Abnormality of |
|
| It is caused when | Poor BLDC Motor | |
9 |
|
| feedback | connection, DRIVE IC, and | ||
BLDC FAN Motor | Er | CF | signal isn ’ t over 115 | TR Tx/Rx between icemaker | ||
| for Mechanic Room |
|
| seconds during BLDC | and main board. | |
|
|
|
| FAN motor operating |
| |
|
|
|
|
|
| |
|
|
|
| Communication Error | Poor Communication | |
| Communication |
|
| connection,Poor TR of | ||
10 | Er | CO | between Micom of Main | Transmitter and Receiver | ||
Error | ||||||
|
|
| PCB and Display Micom | Tx/Rx between icemaker | ||
|
|
|
|
| and main board. | |
|
|
|
|
|
|
- 17 -