Kenmore 795.775636, 795.775796, 795.775646, 795.775736 How to Measure Damper Circuit, Extension

Models: 795.775626 795.775696 795.775726 795.775736 795.775646 795.775636 795.775796

1 78
Download 78 pages 19.02 Kb
Page 50
Image 50

7-7. Damper

Function

The damper supplies the cold air at freezer room to chillroom

 

by using the damper’s plate. Chillroom is colder than before

 

when damper’s plate is open. When damper’s plate is close,

 

chillroom’s temperature will rise.

How to

 

Measure

 

< Damper Circuit >

1 Blue

1 Blue

 

2 Red

 

3 White

3 White

Checj the 1 , 3 4 Tellow

extension

Check the 2 , 4

Check the 1 , 3

Check the resistance between connectors 1,3 and 2,4 .It means check whether or not applying an electric current. If there is resistance, it means the damper not inferiority

Standard

Damper

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Points

Result

 

Test Points

Result

 

 

 

 

 

 

 

 

 

Red and Yellow

373 ~ 456 Ω

 

Blue and White

373 ~ 456 Ω

 

 

 

 

 

 

 

- 50 -