4.How to check the Fan-Error

(1)6871JB1431A ( ~ July 2007)

After sending a signal to the fan, the MICOM checks the BLDC fan motor’s lock status. If there is no feedback signal from the BLDC fan, the fan motor stops for 10 seconds and then is powered again for 15 seconds. To determine that there is a fan motor malfunction,

this process is repeated 5 times. If the fan motor is determined to be defective, the error code will be shown continuously in the display. At this point, there is no further check of the fan motor.

No signal

 

 

 

 

Error Display

15s

 

15s

15s

15s

15s

Normal

10s

10s

10s

 

10s

drive

 

 

 

 

 

 

(2)EBR34917102 ( Aug 2007 ~)

After sending a signal to the fan, the MICOM checks the BLDC fan motor’s lock status. If there is no feedback signal from the BLDC fan, the fan motor stops for 10 seconds and then is powered again for 15 seconds. To determine that there is a fan motor malfunction,

this process is repeated 3 times. If the fan motor is determined to be defective, the error code will be shown in the display for 30 minutes. At this point, the process will be repeated until the fan motor operates normally. If normal operation is achieved, the error display is erased and the MICOM is reset automatically.

No signal

15s

Normal drive

No signal 15s

Pause 30min

10s

10s

15s15s

10s

15s15s

10s

Repeat 15s

Pause 30min

10s

- 43 -

Page 43
Image 43
Kenmore 795.775636, 795.775796, 795.775646, 795.775736, 795.775726, 795.775696, 795.775626 manual How to check the Fan-Error