6-2. Troubleshooting With Error

Freezer Sensor Err or

Is Er-FS dis played?

Yes

Is the connection loose?

Yes

 

Reconnect

Disconnect CON6 and measure

the value. Is resistance value No between pins 11 & 12 of CON6

as below? (BL to BL)

pin11 pin12

Replace F-sensor

No

Power Off

Tip : To protection of MICOM

Test Point

Result

 

 

pin11 to pin12

1.4 ~ 120k‰

 

 

No

Reconnect CON6 and Power ON

If the ER-FS appears, Replace the main PCB. Otherwise, explain to the customer!