Refrigerator Sensor Error

Wiring dia gram

Is Er-rS displayed?

Yes

 

Is the connection loose?

Yes

 

Reconnect

Disconnect CON6 and measure

the value. Is resistance value No between pins 9 & 10 of CON6 as below? (WH to WH)

pin9 pin10

Replace R-sensor

No

Power Off

Tip : To protection of MICOM

Tpin10 pin9

Result

 

 

pin9 to pin10

6 ~ 300 k‰

 

 

No

Reconnect CON6 and Power ON

If the ER-rS appears, Replace the main PCB. Otherwise, explain to the customer!

- 19 -

Page 19
Image 19
Kenmore 795.775696, 795.775796 manual Refrigerator Sensor Error, Wiring dia gram, Yes Is the connection loose?, Pin9 pin10