1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE SERVICING

IMPORTANT – RECONNECT ALL GROUNDING DEVICES

All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.

1-2 IMPORTANT NOTICE

This information is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.

1-3 ELECTRICAL SPECIFICATIONS

Temperature Control (F

 

) ...-6°F to +8°F

Defrost Control

Total Comp Running Time 7 hrs

Defrost Thermostat

46°F

Electrical Rating : 115VAC, 60Hz

1-5 A

Maximum Current Leakage

0.5 mA

Maximum Ground Path Resistance

0.14 Ohms

Energy Consumption

25 cu.ft. 579 kWh/yr (Energy Star)

1-4 NO LOAD PERFORMANCE CONTROL POSITION: MID/MID

And Ambient of:

70°F

90°F

Fresh Food, °F

33°F to 41°F

33°F to 41°F

Frozen Food, °F

-4°F to +4°F

-4°F to +4°F

Percent Running Time

35%-45%

50°F-70°F

1-5 REFRIGERATION SYSTEM

Minimum Compressor Capacity Vacuum

............... 21 MIN.

Minimum Equalized Pressure

 

@ 70°F

49 PSIG

@ 90°F

56 PSIG

Refrigerant R134a

4.41 oz.

Compressor

956 BTU/hr

1-6 INSTALLATION

Clearance must be provided at top, sides and rear of the

refrigerator for air circulation.

 

AT TOP

2 in

AT SIDES

1 in

AT REAR

1 in

1-7 REPLACEMENT PARTS

Relay

6748C-0004D

Overload

6750C-0004R

Defrost Thermostat

6615JB2005H

Defrost Heater

5300JK1005D

Evaporator Fan Motor

4681JK1004E

Capacitor (Running)

0CZZJB2014B

 

*0CZZJB2012H

 

*0CZZJB2012K

Compressor (Hi-Side)

TCA31748001

Evaporator (Lo-Side)

5421JJ1007A

Condenser

5403JJ1004B

Dryer

5851JA2002P

Condenser Fan Motor

4681JB1029D

Temperature Control

3551JA1132L(SW)

 

3551JA1132M(ST)

 

3551JA1132N(WB)

 

3551JA1132P(BI)

Main Control

EBR3491102

Ice Fan Motor

4681JB1029E

*OPTIONAL

 

1-8 AIR FLOW / CIRCULATION D’AIR

EVAPORTOR FAN MOTOR

CONDENSER FAN MOTOR

ICE

ROOM