Crush Mode Doesn't work

CON2

5

SB

 

4

1

 

 

 

Auger

 

 

 

 

 

7

 

 

 

V

Dispenser

 

 

 

1

2

Motor

 

 

Lever S/W

Housing-B

 

PCB

 

WH

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

CON3

 

RD

 

 

 

 

 

9

 

 

 

 

 

 

 

1

1

Solenoid

 

 

 

 

 

 

 

 

 

S

 

 

BL

 

2

2

Dispenser

 

 

 

 

 

 

 

 

 

Wiring diagram

Display PCB

Yes

Is the connection loose?

 

No

Reconnect

In Crush Mode,

Is the voltage between pin5 No of CON2 and pin3 of CON3

like as below, while pushing the lever switch?

Replace

Dispenser

PCB

CON2

Pin5 SB

CON3

Pin3 WH

Output voltage of Auger motor

Level switch

Test Point

Result

 

 

 

Pushing

pin5 to pin3

115 V

 

 

 

Normal

pin5 to pin3

0 V

 

 

 

Yes

- 32 -