Crush Mode Doesn't work
CON2 | 5 | SB |
| 4 | 1 |
|
|
| Auger | ||||
|
|
|
| |||
| 7 |
|
|
| V | |
Dispenser |
|
|
| 1 | 2 | Motor |
|
| Lever S/W |
| |||
PCB |
| WH |
| |||
|
|
| ||||
3 |
|
|
|
| ||
|
|
|
|
|
| |
CON3 |
| RD |
|
|
|
|
| 9 |
|
|
|
| |
|
|
| 1 | 1 | Solenoid | |
|
|
|
| |||
|
|
|
|
| S | |
|
| BL |
| 2 | 2 | Dispenser |
|
|
|
| |||
|
|
|
|
|
Wiring diagram
Display PCB | Yes | |
Is the connection loose? | ||
|
No
Reconnect
In Crush Mode,
Is the voltage between pin5 No of CON2 and pin3 of CON3
like as below, while pushing the lever switch?
Replace
Dispenser
PCB
CON2
Pin5 SB
CON3
Pin3 WH
Output voltage of Auger motor
Level switch | Test Point | Result |
|
|
|
Pushing | pin5 to pin3 | 115 V |
|
|
|
Normal | pin5 to pin3 | 0 V |
|
|
|
Yes
- 32 -