4. diagnosis

1Power Source.

Remove PTC-Starter from Compressor and measure voltage between Terminal C of Compressor and Terminal 5 or 6 of PTC.

No Voltage.

(Rated Voltage

YES

±10%)?

2

 

OLP disconnected?

YES

5

Replace OLP.

NO

Check connection

 

condition.

 

Reconnect.

 

 

Applied voltage isn't

 

 

 

Advise customer that

 

5

 

 

 

 

 

 

 

 

 

 

 

in acceptable range.

 

 

 

power supply needs to be

 

 

 

 

 

 

(115V ±10%)

 

 

 

checked by an electrician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2Check resistance of Motor Compressor.

Check

3resistance of PTC-Starter.

4Check OLP.

Check resistance between M-C, S-C and M-S in Motor Compressor.

Check resistance of two terminals in PTC-Starter.

Check resistance of two terminals in OLP.

The range of resistance is between 1~50Ω (ok)

 

 

 

3

Open or short Replace

 

 

 

Compressor.

3

4

5

Reference 5-2

Reference 5-3

5

Check starting state.

Check the power supply under load. (Compressor attempting to re-start after being off for 5 minutes).

 

 

YES

 

 

YES

 

Compressor

 

 

 

 

 

 

 

 

Supply

 

 

Did

 

 

is OK

 

 

voltage rating

 

 

compressor

 

 

 

 

 

 

 

 

 

 

 

with ±10%.

 

 

start?

 

 

 

 

 

 

 

 

Replace the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

compressor

 

 

 

 

 

 

 

 

 

 

NO

1

 

- 14 -

Page 14
Image 14
Kenmore 795.775796, 795.775636, 795.775646, 795.775736, 795.775726, 795.775696, 795.775626 manual Diagnosis, Compressor