Over cooling in the refrigerator compartment

MAIN PWB

Yes

Reconnect

Enter the TEST 2 MODE

No

Is the connection loose?

Does the cold-air coming out

 

 

 

 

 

 

of the top of the main duct.?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the Damper itself

CON3

No

 

 

Enter the TEST 1 MODE

 

 

Yes

Replace

Is the voltage between

Damper

 

Pins 4 and pin 12 of

 

 

 

 

CON3 like as below?

 

 

Yes

Checking Damper itself Is the resistance Values between (1) & (4),

(2) & (3) like as below?

(3)BL

(4)YL

Yes

(1)RD

(2)WH

Replace Damper

Pin12 Pin4

BK BL

CON3

Resistance of Damper

Test Point

Ressult

Voltage of Compressor

Test Point

Ressult

 

 

pin4 to pin12

115 V

 

 

Yes

Check the Fan operation by

placing your hand in front Yes of the vents to feel for any

cold air flow.

Door

Fan-Motor

 

 

Open

OFF

 

 

Closed

ON

 

 

Replace Fan

(1)to (4) 373 ~456 Ω

(2)to (3) 373 ~456 Ω

Yes

No

- 40 -

Page 40
Image 40
Kenmore 795.775696, 795.775796, 795.775636, 795.775646, 795.775736 Over cooling in the refrigerator compartment, BK BL CON3