Icing Room Fan Error

Main PWB

CON4

4

5

6

RD

BL

BN

4

4

5

5

6

6

Housing

BK

 

RD

Icing

PR

FAN

 

Wiring diagram

Is Er-IF displayed?

Yes

Is the connection loose?

Yes

Reconnect

Does the cold-air come out

N0

of the side duct?

 

Yes

Check fan motor (Connector, Frozen,Locked)

N0

Reset and

Replace

Is the feedback voltage

 

Replace

between pin5 and pin6 of

N0

Main PCB

CON4 like as below?

 

 

 

(from motor to main board)

 

 

 

 

Enter the TEST 1 MODE N0 Is the output voltage between pin4 and pin5 of

CON4 like as below?

Pin4 RD Pin4 BL

Icing Fan Voltages

Test Point

 

Ressult

 

 

 

pin4 to pin5

 

12 ~ 16 V

 

 

 

Yes

 

Main PCB

Pin5 BL

Pin6 BN

Feedback Voltages

Test Point

 

Ressult

 

 

 

pin5 to pin6

 

1 ~ 4 V

 

 

 

Yes

 

Explain to the customer!