Master Lock B70CEH Storing Transporting, Or Shipping, Preventative, Maintenance, Schedule, occur

Models: B35CEH B100CEH B150CEH B70CEH

1 108
Download 108 pages 2.17 Kb
Page 8
Image 8
STORING,

R

PORTABLE FORCED AIR HEATERS

STORING,

TRANSPORTING, OR SHIPPING

Note: If shipping, transport companies re- quire fuel tanks to be empty.

1.Drain fuel tank.

Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.

2.Replace drain plug if provided.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur- ing future use.

4.Replace fuel cap or drain plug. Prop- erly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

PREVENTATIVE

WARNING: Never service heater

MAINTENANCE

while it is plugged in, operating, or hot.

SCHEDULE

Severe burns and electrical shock can

occur.

 

 

Item

How Often

How To

Fuel tank

Flush every 150-200 hours of

See Storing, Transporting, or Ship-

 

operation or as needed

ping

Air output and

Replace every 500 hours of

See Air Output, Air Intake, and Lint

lint filters

operation or once a year

Filters, page 10

Air intake filter

Wash and dry with soap and

See Air Output, Air Intake, and Lint

 

water every 500 hours of op-

Filters, page 10

 

eration or as needed

 

Fuel filter

Clean twice a heating season

See Fuel Filter, page 8

 

or as needed

 

Ignitor

No maintenance required

 

Fan blades

Clean every season or as

See Fan, page 13

 

needed

 

Motor

Not required/permanently lu-

 

 

bricated

 

TROUBLESHOOTING

PREVENTATIVE WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

HEATER WITH FUSED OR NON-FUSED IGNITION CONTROL ASSEMBLY

FAULT CONDITION

POSSIBLE CAUSE

REMEDY

Motor does not start five seconds after heater is plugged in (ON/OFF switch light remains on)

1. Bad electrical connection between motor

1. Check all electrical connections. See

and ignition control assembly or ignition

Wiring Diagram, page 23

control assembly and power cord

 

 

 

WARNING: High voltage!

 

 

 

 

 

 

 

2.

Binding pump rotor

2.

If fan does not turn freely, see Pump

 

 

 

 

Rotor, page 12

3.

Defective ignition control assembly

3.

Replace ignition control assembly

4.

Defective motor

4.

Replace motor

6

105398

Page 8
Image 8
Master Lock B70CEH, B35CEH Storing Transporting, Or Shipping, Preventative, Maintenance, Schedule, Troubleshooting, occur