Define Open Time | Function 18 |
|
|
Level: Master
This function SETS the time the lock will REMAIN OPEN to allow access. The time INTERVAL may vary between
ENTRIES |
| VISUAL / AUDIO |
1. |
| # |
Valid User Code |
| |
2. | 1 | 8 * |
Function Number | ||
3. |
| * |
Set Time |
| |
|
| 1 to 9 Seconds |
4. |
| * |
Exit |
| |
See Note |
|
|
Note
The DEFAULT for this function is 3 SECONDS.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL
Page 18
Function 30 | Manual Passage Mode |
|
|
Level: Master
Manual Passage Mode is designed to allow free access to the door.
There are two types of passage mode:
1.Entered at the door.
2. Schedule Passage Mode. (See Func. 05.)
To CLOSE the passage function and return the door to its normal security level, enter "0".
To OPEN the passage function, enter "1".
| ENTRIES |
|
| VISUAL / AUDIO |
1. | Valid User Code |
|
| # |
|
|
| ||
2. | Function Number | 3 | 0 | * |
| ||||
3. | Select One: |
|
|
|
| (0) CLOSE |
| 0 | * |
| (1) OPEN |
| 1 | * |
4. | Exit |
|
| * |
|
|
| ||
| See Note |
|
|
|
Note
There is NO additional POWER USAGE while the door is in passage mode.
The DEFAULT for this function is “0” CLOSE.
Function can be used to OVERRIDE SCHEDULED PASSAGE MODE by entering “0” Closed.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL
Page 19