Initialize Great Grand Master

Level: Master

When the Great Grand Master (GGM) is entered it has the two components that are found in all codes.

1.User ID (UID) 3 to 4 DIGITS2.Pin Number (PIN) 3 to 6 DIGITS/ALPHA/MULTIPLE KEY DEPRESSIONS3.UID and PIN have a MAXIMUM TOTAL LENGTH of 9 DIGITS.

The length of the GGM’s UID and PIN determine the length of all FUTURE MANAGEMENT and USER CODES. This allows the GGM to set the overall level of security for the lock at the time of initialization.

ENTRIES

VISUAL / AUDIO

1.

9991234 *

Factory Code

2.

#

User ID

User Defined (3-4 Digits)

 

3.

#

PIN

 

3 to 6 Alpha-Numeric

Note

UID MUST be DIGITS ONLY.

PIN CAN be ALPHA/NUMERIC/MULTIPLE KEY DEPRESSIONS.

No group number is given to the GGM.

Only ONE GGM per lock.

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Page 2

Function 12

Set Time

 

 

Level: Master

TIME MUST BE SET PRIOR TO ACTIVATING SCHEDULING.

This function SETS the INTERNAL TIME of the LOCK. The lock uses military time and is automatically updated when the upload/download module (IDT) is used. Ex. 1530=3:30 p.m.

ENTRIES

 

 

VISUAL / AUDIO

1.

 

 

 

Valid User Code

 

 

#

2.

1

2

*

Function Number

3.

 

 

*

Time

 

 

Mgmt. Defined Hours

Minutes

4.

 

 

*

Exit

 

 

See Note

 

 

 

Note

TIME MUST BE SET PRIOR TO ACTIVATING SCHEDULING.

The Default for this function is DAYLIGHT SAVINGS TIME ENABLED.

To DISABLE DAYLIGHT SAVINGS time, press “0” as the LAST DIGIT of the time entry.

Ex. 18380 = DISABLED 1838= ENABLED

For Military Time Conversion Chart, see page 30.

ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Page 3