Fail Secure

Function 36

 

 

Level: Grand Master

THIS FUNCTION IS ONLY INTENDED FOR USE IN BATTERY POWERED UNITS.

In case the low battery warning goes unnoticed, (See Battery Information page iv) and the lock runs out of power, this function ensures that the E72 will fail in a secured state. At that time, a key will be required to open the E72. If this function is not used, the lock will fail in the last state the lock was in.

EGRESS IS ALWAYS PERMITTED.

TO ENABLE Fail Secure, enter "0". This will set a POWER RESERVE to ENSURE the lock will fail CLOSED.

TO DISABLE Fail Secure, enter "1". This will allow the lock to fail in its last state - either open or closed.

ENTRIESVISUAL / AUDIO

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid User Code

 

 

 

 

#

 

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function Number

 

 

 

 

 

 

 

 

 

3

 

6

 

 

 

*

 

3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select One:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0) FAIL SECURE

 

 

0

 

 

*

 

(ENABLED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) DISABLE

 

 

1

 

 

*

 

4.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

See Note

 

 

 

 

 

 

 

 

Note

The DEFAULT for this function is “1” DISABLED.

ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Page 24

Function 37

Set Alternative Terminator

 

 

Level: Grand Master

This function increases the SECURITY of the lock by REVERSING the TERMINATOR and PROGRAMMING KEYS. This reversal adds another level of complexity to any attempt at hacking codes. (For more information on the terminators, see page iii.)

To USE DEFAULT, enter "0". (“*” is the terminator and “#” is the programming key)

To ENABLE REVERSE, enter "1" (“#” is the terminator and “*” is the programming key).

ENTRIESVISUAL / AUDIO

1.

 

 

 

 

 

 

 

 

Valid User Code

 

 

 

 

#

 

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function Number

 

 

 

 

 

 

 

3

 

7

 

*

 

 

 

 

 

 

 

 

 

3.Select One:

(0) DEFAULT “*

0

*

(1) REVERSED “#”

1

*

 

4.

 

*

Exit

 

See Note

 

 

Note

 

 

The DEFAULT for this function is

“0” “*as terminator.

ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.