First Supervisor to Arrive | Function 31 |
|
|
Level: Grand Master
This function will override the set schedule, denying USERS access until a user with a MINIMUM ACCESS OF SUPERVISOR
To DISABLE the first supervisor function, enter "0".
To ENABLE the first supervisor function, enter "1".
| ENTRIES |
|
| VISUAL / AUDIO |
1. | Valid User Code |
|
| # |
|
|
| ||
2. | Function Number | 3 | 1 | * |
| ||||
3. | Select One: |
|
|
|
| (0) DISABLE |
| 0 | * |
| (1) ENABLE |
| 1 | * |
4. | Exit |
|
| * |
|
|
| ||
| See Note |
|
|
|
Note
The DEFAULT for this function is “0” DISABLED.
At 0000 HOURS this function RESETS.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL
Page 20
Function 32 | Pin Only Entry |
|
|
Level: Grand Master
Function allows a SHORTER LENGTH OF CODE to be entered by the user to gain access. When ENABLED, user enters their PIN number FOLLOWED BY “*”.
The POSSIBLE PROBLEMS this function poses are:
•SECURITY of the lock is COMPROMISED by fewer possible entries;
•Possibility of DUPLICATE PIN NUMBERS;
•AUDIT TRAIL is NOT RELIABLE with this function due to restricted retrieval information.
To ENABLE the PIN ONLY, enter "0".
To ENABLE the UID & PIN, enter "1".
ENTRIES |
| VISUAL / AUDIO |
1. |
|
|
Valid User Code |
| # |
2. | 3 | 2 * |
Function Number |
3.Select One:
| (0) PIN ONLY |
|
|
|
|
|
| 0 |
|
| * |
| |
|
|
|
|
| ||
| (1) UID & PIN |
|
|
|
|
|
| 1 |
|
| * |
| |
|
|
|
|
| ||
4. |
|
|
|
|
|
|
|
|
|
|
|
| |
Exit |
|
|
|
|
| |
|
|
| * |
| ||
| See Note |
|
|
|
|
|
|
|
|
|
|
|
|
Note
The DEFAULT for this function is “1” (UID and PIN REQUIRED for entry).
User MUST enter PIN NUMBER and “*” to gain access.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.
IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL
Page 21