Maytag 2006 owner manual Appliances, Monitor Panel, Monitor Wire Connections

Models: 2006

1 101
Download 101 pages 27.2 Kb
Page 96
Image 96
MONITOR PANEL

Appliances

MONITOR PANEL

Micropulse Systems Monitor

CATCON PRODUCTS INC.

817-921-2188 sales@catconproducts.com techsupport@catconproducts.com

H

The MicroPulse System makes use of a single solid-state sensor per tank. The

MicroPulse sensor measures the static (head) pressure at the bottom of the tank and

transmits this information to the MicroPulse System Monitor.  Knowing this pressure

 

value, after a one-time calibration has been performed, the MicroPulse System will

 

calculate and accurately display the tank level in 1/8 increment.

 

A single sensor is installed on the sidewall of each tank, near the bottom, via a 3/4”

 

female NPT spin-in thread. The sensor is solid state, there are no moving parts to wear

 

or maintain.  Because the principle of operation does not involve any electrical current

 

flow through the tanks contents (conducted or induced), the nature of the fluid in the

 

tank is unimportant. 

The monitor system has been calibrated at the factory and should never need another calibration. If you feel the system is not operating correctly, please contact CATCON Products or a local Airstream dealer. The following instructions are provided for quali- fied service technicians.

MONITOR WIRE CONNECTIONS

 

Red

12VDC, Battery Only

Black

Ground, Battery Only

Purple

Water Pump, 15A, 12VDC

White

LPG Sensor, 90 ohm

Fresh

Fresh Tank Sensor

Gray 1

Gray 1 Sensor

Gray 2

Gray 2 Sensor

Black

Black Sensor