Function

Controls each driving system (VALVE, DOOR S/W, DRAIN-MOTOR) by turning RELAY or TRIAC on/off.

Description

-MICOM outputs a high signal of 5V from pin # 1 - 7 of IC7 and IC9.

-Then, pin # 10 to 16 of IC7 and IC9 are electrically grounded (0V).

-When pin # 10 to 16 are grounded, this creates an electric potential difference from the 12V that turns on RELAY 5,6,7 and TRIAC2,3,4,5.

-The operating parts (VALVE, DRAIN-MOTOR, DOOR S/W) connected to CN9 turn on if they are supplied with power.