71#DOLJQPHQW#DQG#DGMXVWPHQWV

7041#Huuru#lwhpv#dqg#Gldjqrvwlf#Frghv

1.An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

Display

Description

Trigger

Action Taken

 

 

 

Check for:

 

 

The Thermistor

- Clogged lint screen.

 

Dryer Thermistor Short

- Restricted vent sys-

tS

resistance is

Sensed

tem.

 

very low.

 

 

- Check Thermistor

 

 

 

 

 

 

resistance.

 

 

 

Check for:

 

 

The Thermistor

- Clogged lint screen.

 

Dryer Thermistor Open

- Restricted vent sys-

tO

resistance is

Sensed

tem.

 

very high.

 

 

- Check Thermistor

 

 

 

 

 

 

resistance.

 

 

 

Check for:

 

 

Running the

- Close the door, and

 

 

run the dryer

do

Door Open

dryer with door

- Loose or open wire

 

 

open

 

 

terminals in Door

 

 

 

 

 

 

Sense circuit.

 

 

 

Check for:

 

 

Invalid power

- Not using regular

 

Power source frequen-

power source

FE

source

cy Error

frequency

 

Frequency

 

 

- Invalid power fre-

 

 

 

 

 

 

quency sense circuit

 

 

Invalid state for more

Check for:

 

 

- Loose or open wire

dF

Door Circuit Failure

than 256

terminals in Door

 

 

milliseconds

 

 

Sense circuit.

 

 

 

 

 

 

Check for:

 

 

Invalid heating Temp in

- Restricted vent sys-

hE

Heater Error

tem.

running the dryer

 

 

- Check Thermistor

 

 

 

 

 

 

resistance.

 

 

Invalid state

Check for:

bE

Button Error

of key circuit short

- Display PCB key

 

 

for 75secs

circuit short or not

 

 

Invalid Dry

Check for:

 

 

- Sensor bar Open

od

Over Dry

time in

- using Adjust time Up

 

 

excess Dry time

 

 

excessively

 

 

 

 

 

Invalid state

Check for

Et

EEprom Fail

of Eeprom

- PCB on EEprom

 

 

communication

circuit

4-1