45081#Vhqvru#Ghwhfwlrq#Flufxlw
▶Function
Detects signals from the sensor and controls the current system.
▶Description
-The water level sensor is connected to pin 4 of CN7.
-The frequency of the level sensor changes according to the water amount in the tub.
-Then, the frequency is input to MICOM pin 48 for detecting the water amount.
-The DHSEH sensor is connected to CN7 pin 5 and CN6 pins 3,4.
-The resistance of the temp. sensor changes according to the ambient temperature. The changed resistance is applied to R50 and R51.
-The voltage applied to R50 and R51 is decided according the temp. MICOM stores
the value.
-When voltage is applied to MICOM pins 22 and 23, MICOM compares it to the predefined one before detecting the current temp.