Maytag HRX52DERS manual Draining, Thermostat Removal/Replacement, Service and Maintenance cont’d

Models: HRX40DERS HRX82DERT HRX40DERT HRX52DERS HRX66DERT HRX52DERT HRX30DERT

1 32
Download 32 pages 12.19 Kb
Page 17
Image 17
Draining

Service and Maintenance (cont’d)

Draining

The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.

1.Before beginning turn “OFF” the electric power supply to the water heater.

Thermostat Removal/Replacement WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned “OFF”. Failure to do this could result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

2.CLOSE the cold water inlet valve to the water heater.

3.OPEN a nearby hot water faucet and leave open to allow for draining.

4.Connect a hose to the drain valve and terminate to an ade- quate drain or outdoors.

5.OPEN the water heater drain valve to allow for tank draining.

NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to termi- nate to an adequate drain.

6.Close the drain valve.

7.Follow “Filling the Water Heater” instructions in the “Instructions for Installation” section.

Thermostat Removal/Replacement

1.Turn “OFF” the electrical power to the water heater at the junction box.

Manual background WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned “OFF”. Failure to do this could result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

2.Remove the access panel and the insulation block and pad.

3.Lift out the tab as shown below to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.

Manual background Lift out tab to unclip terminal cover from thermostat.

LOWER THERMOSTAT

UPPER OR LOWER

WITHOUT HIGH LIMIT

THERMOSTAT WITH

 

HIGH LIMIT

8. Turn “ON” power to the water heater.

Manual background CAUTION

Never use this water heater unless it is completely full water. To prevent damage to the tank and heat- ing element, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” power.

4.Remove the two wires attached to the thermostat.

5.Remove the thermostat from behind the thermostat bracket.

6.Disconnect wires from thermostat and slide out of the bracket.

7.Place the new lower thermostat in the bracket making sure it fits firmly against the tank.

8.Attach the wires to the new thermostat.

NOTE: Some of the terminals may require straight-in wiring through an eye-opening. If wires are now looped, re- cut and strip wire 38to a straight length and insert.

17

Page 17
Image 17
Maytag HRX52DERS, HRX30DERT, HRX52DERT, HRX66DERT Draining, Thermostat Removal/Replacement, Service and Maintenance cont’d