Maytag HRX52DERT, HRX30DERT Troubleshooting cont’d, Not Enough Or No Hot Water, Water Is Too Hot

Models: HRX40DERS HRX82DERT HRX40DERT HRX52DERS HRX66DERT HRX52DERT HRX30DERT

1 32
Download 32 pages 12.19 Kb
Page 22
Image 22
Troubleshooting (cont’d)

Troubleshooting (cont’d)

1.Before beginning, turn “OFF” electrical power supply to the water heater.

NOT ENOUGH OR NO HOT WATER WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned “OFF”. Failure to do this could result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

2.Remove the two screws securing the access panel and remove panel.

3.Remove the insulation block and pad to expose the termi- nal cover.

4.Reset the high limit by pushing in the red button marked “RESET”.

WATER IS TOO HOT RESET BUTTON

5.Replace the insulation block and pad so that it completely covers the thermostat and element.

6.Replace the access panel.

7.Turn “ON” electric power to the water heater.

Manual background CAUTION

If the high limit must be reset again, call a Maytag Service Specialist at 1-800-365-0024 for an autho- rized servicer to find out why the high limit turned “OFF” the electric power.

NOT ENOUGH OR NO HOT WATER

1.In a new installation, the water heater may not be proper- ly connected. Make sure the cold water supply valve is open. Review and check piping installation. Make sure that the cold water line is connected to the cold water inlet to the water heater and the hot water line to the hot water outlet on the water heater.

2.Make sure the electrical supply to your water heater is “ON”.

3.Check for loose or blown fuses in your water heater cir- cuit. Circuit breakers weaken with age and may not han- dle their rated load and should be replaced.

4.Make certain the disconnect switch, if used, is in the “ON” position.

5.Check to see the electric service to your house has not been interrupted. If this is the case, contact the electric company.

6.Are the thermostats set to the desired temperature? See “Temperature Regulation” section.

7.If you had experienced very hot water and now no hot water, the problem may be due to the high temperature shut off system. See “High Temperature Shut Off System” in the “Troubleshooting” section.

8.During very cold weather, the incoming water will also be colder and it will require a longer time to become heated.

9.The hot water usage may exceed the capacity of the water heater. If so, wait for water heater to recover after abnor- mal demand. Also examine pipes and faucets for possible water leaks.

10.If you can not determine the problem, then call the Maytag Service Department.

WATER IS TOO HOT

Adjust the thermostat to a lower setting. See the “Temperature Regulation” section.

22

Page 22
Image 22
Maytag HRX52DERT, HRX30DERT, HRX66DERT, HRX52DERS manual Troubleshooting cont’d, Not Enough Or No Hot Water, Water Is Too Hot