Instructions for Installation (cont’d)

Temperature-Pressure Relief Valve

WARNING

At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve cer- tified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equip- ment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22 • CSA 4.4 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4 by a nationally rec- ognized testing laboratory that maintains periodic inspec-

WARNING

The temperature-pressure relief valve must be manu- ally operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually dis- charged will not cause any bodily injury or property damage because the water may be extremely hot.

If after manually operating the valve, it fails to com- pletely reset and continues to release water, immedi- ately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.

tion of production of listed equipment or materials.

HOT

COLD

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 lbs. p.s.i.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3412 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z21.22 • CSA 4.4 and ASME, may require a valve model dif- ferent from the one furnished with the water heater.

Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve.

For safe operation of the water heater, the relief valve must not be removed from it’s designated opening or plugged.

The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be cer- tain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the dis- charge pipe.

Must terminate at an adequate drain.

Must not have any valve between the relief valve and tank.

HOT COLD

CONDUIT

TEMPERATURE-

PRESSURE RELIEF VALVE

DISCHARGE PIPE (Do not cap or plug)

6AIR GAP

FLOOR DRAIN

WARNING “RELIEF VALVE OPENING”

This water heater is provided with a combination Temperature-Pressure Relief Valve listed as complying with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANS Z21.22 and the code requirements of ASME.

Your local jurisdictional authority, while mandating the use of a Temperature-Pressure Relief Valve complying with ANS Z21.22 and ASME, may require a valve model different from the one furnished with the water heater. Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed Temperature-Pressure Relief Valve installed in the designated opening in the water heater.

TANK

 

 

 

￿

JACKET

TANK

 

 

 

 

BRASS

 

 

 

￿

COUPLING

FITTING

 

￿

 

 

 

 

T&P RELIEF

 

￿

TEMPERATURE-

VALVE PROBE

 

MUST EXTEND

 

PRESSURE

INTO TANK

 

 

￿

RELIEF VALVE

(13/8" x 3/4")

 

 

 

 

T&P

BRASS

 

 

 

 

￿

 

 

 

SHANK

NIPPLE

 

 

 

 

 

 

LENGTH

If a short shank (less than 2") temperature-pressure relief valve is to be installed (as shown), a nipple and coupling must be used.

If a long shank (2" or longer) is to be installed, do not use the nipple and coupling.

“Install Temperature-Pressure protective equipment required by local codes, but not less than a combina- tion Temperature-Pressure Relief Valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot-Water Supply Systems, ANS Z21.22 by a nationally recognized test- ing laboratory that maintains periodic inspection of production of listed equipment or materials. The valve must be oriented, provided with tubing, or otherwise installed so that discharge can exit only within 6 inches above, or at any distance below the structural floor, and cannot contact any live electrical part.”

For safe operation of the water heater, the Relief Valve must not be removed or plugged.

See manual heading - “Temperature-Pressure Relief Valve” for installation and maintenance of Relief Valve, discharge pipe and other safety precautions.

11

Page 11
Image 11
Maytag HRX40DERT, HRX30DERT manual Temperature-Pressure Relief Valve, Tion of production of listed equipment or materials

HRX40DERS, HRX82DERT, HRX40DERT, HRX52DERS, HRX66DERT specifications

The Maytag HRX series, comprising the HRX66DERT, HRX82DERT, HRX30DERT, HRX52DERT, and HRX40DERT models, is designed for those seeking high-quality refrigeration solutions that combine reliability, innovative features, and advanced technology. Each model in this series showcases an array of characteristics that cater to the evolving needs of modern households.

One of the standout features of the Maytag HRX series is its powerful cooling performance, which is achieved through the use of Precision Cooling technology. This technology ensures that your food remains fresh for longer by maintaining optimal humidity levels and temperatures. With a dedicated cooling system, the HRX models effectively reduce temperature fluctuations, preserving the quality and longevity of your groceries.

Another key characteristic of the Maytag HRX series is the SmartSeal design that prevents air leaks and enhances energy efficiency. This feature not only helps to save on energy bills but also contributes to the appliance's overall sustainability. The Energy Star certification found in these models indicates adherence to strict energy efficiency guidelines, ensuring that users enjoy lower environmental impact without compromising performance.

The internal configuration of each model offers adjustable shelving and custom storage options to maximize space. The slide-out shelves provide easy access, while the spacious compartments cater to various food items. The inclusion of bins dedicated to fruits and vegetables ensures that perishables are organized and easily accessible.

The HRX series also boasts advanced temperature management systems. Users can enjoy the convenience of an external temperature display, allowing for quick adjustments without the need to open the refrigerator door. This feature not only increases efficiency but also contributes to maintaining optimal storage conditions.

In terms of durability, the Maytag HRX refrigerators are equipped with robust materials, including stainless steel finishes and reinforced hinges. These constructions ensure that the appliances withstand daily use while maintaining a modern aesthetic that complements any kitchen decor.

In summary, the Maytag HRX66DERT, HRX82DERT, HRX30DERT, HRX52DERT, and HRX40DERT models are exemplary choices for anyone seeking reliable refrigeration. With features like Precision Cooling, SmartSeal design, generous storage options, and user-friendly technology, they are built to exceed user expectations while providing an energy-efficient and durable solution for preserving food freshness. Whether for a large family or a smaller household, the HRX series caters to various needs and preferences, making them a valuable addition to any kitchen.