Maytag W10258096A To Convert Surface Burners, A B C D, LP Gas Orifice Spud Chart, Burner Rating

Models: W10258096A

1 40
Download 40 pages 20.46 Kb
Page 15
Image 15
To Convert Surface Burners

3.Turn the 1.65 mm Natural gas broil burner orifice hood counterclockwise to remove.

A BLP Gas Orifice Spud ChartBurner RatingA

To Convert Surface Burners

1.If installed, remove the burner grates.

2.Remove the burner caps.

3.Using a Phillips screwdriver, remove the burner base.

A Color

C

B

D

A. 1.65 mm Natural gas broil burner orifice hood

4.Install the Number 57 LP gas broil burner orifice hood, turning it clockwise 4 or 5 turns. Do not overtighten.

57 Size A

A. Number 57 LP gas broil burner orifice hood

5.Place the broil burner on the broil burner orifice hood. Insert the broil burner locator pin in the hole in the oven back.

6.Position the broil burner against the roof of the oven cavity and attach with screw.

A B

ID NumberC

D

A. Broil burner orifice hood

B. Broil burner

C. Broil burner locator pin

D. Broil burner locator hole

A. Burner cap

B. Gas tube opening

C. Burner base screws

D. Burner base

4.Apply masking tape to the end of a ⁹⁄₃₂" (7.0 mm) nut driver to help hold the Natural gas orifice spud in the nut driver while changing it. Press nut driver down onto the Natural gas orifice spud and remove by turning it counterclockwise and lifting out. Set the Natural gas orifice spud aside.

A

A. Natural gas orifice spud

Use the following chart for correct LP gas orifice spud for each burner. Refer to the rating plate on the lower right side of the front frame for proper sizing of LP gas orifice spuds for each burner location.

LP Gas Orifice Spud Chart

Burner Rating

Color

Size

ID Number

4,000 BTU

Blue

0.64 mm

64L

5,000 BTU

Yellow/white

0.70 mm

70L

7,000 BTU

Yellow/green

0.84 mm

84L

8,000BTU

Yellow/black

0.85 mm

85L

9,100 BTU

Clear

0.91 mm

91L

10,500 BTU

Green

0.97 mm

97L

11,000 BTU

Yellow/brown

0.99 mm

99L

14,000 BTU

Red

1.14 mm

114L

14,200 BTU

Yellow/orange

1.07 mm

107L

 

 

 

 

5.Replace the Natural gas orifice spud with the correct LP gas orifice spud. See the “LP Gas Orifice Spud Chart.”

6.Replace burner base and hand tighten the screws.

15

Page 15
Image 15
Maytag W10258096A To Convert Surface Burners, A B C D, LP Gas Orifice Spud Chart, Burner Rating, Color, Size, ID Number