Installation
CLEARANCES TO COMBUSTIBLES:
Back Wall | 3" |
| (7.5cm) |
| 4" (10cm) |
8" |
|
(20cm) |
|
Side Wall |
|
Figure 4: Mini Clearance to Combustibles.
Use the Mini’s Hearth Pad (part #
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.
Side wall to unit | 8 inches | (20 cm) |
Back wall to unit | 4 inches | (10 cm) |
Corner to unit | 3 inches | (7.5 cm) |
ALCOVE CLEARANCES:
This unit may be installed in an alcove. Maintain these clearances to combustibles.
Minimum Alcove width | 36 inches | (91.5 cm) |
Minimum Alcove height | 48 inches | (122 cm) |
Maximum Alcove depth | 30 inches | (76 cm) |
Install vent at clearances specified by the vent manufacturer.
��� |
�������� |
��� |
������ |
��� |
������� |
Figure 5: Mini Minimum Alcove Size.
7