Meridian Audio DILA1080pHD warranty Replacing the Lamp, Light-source Lamp and Lamp Usage Time

Models: DILA1080pHD

1 40
Download 40 pages 29.62 Kb
Page 28
Image 28
Replacing the Lamp

Replacing the Lamp

Light-source Lamp and Lamp Usage Time

The light-source lamp has a service life. The life of lamps used for this unit is about 2000 hours.

The lamp life of 2000 hours is merely the average life span of lamps and we do not provide any guarantee for this figure. The lamp life may not reach 2000 hours depending on the operating conditions.

When the light-source lamp approaches the end of its service life, deterioration progresses rapidly. Get ready or replace with a new lamp (lamp unit) when the accumulated lamp usage time exceeds 1900 hours. Depending on the operating conditions, the lamp may have to be exchanged earlier. If the image is dark or color tone abnormal, replace the lamp as soon as possible. You can also check the accumulated hours of usage. Please refer to the “Lamp Time” item of the “Information” menu. (Pages 22, 25)

Please consult your authorized dealer when purchasing a new lamp unit.

Replacement Lamp (Lamp Unit) Part No.: BHL 5006-S

When the lamp usage time exceeds 1000 hours

A message indicating “1000 h” will be displayed on the screen.

Press the [EXIT] button to clear the display.

When the lamp usage time exceeds 1900 hours The [LAMP] indicator lights up.

When starting projection after lamp usage time exceeds 1900 hours

The “Lamp replacement” message will be displayed on the screen.

Press the [EXIT] button to clear the display.

When lamp usage time exceeds 2000 hours The [LAMP] indicator starts to blink.

The “Warning” and “Lamp replacement” messages will be displayed on the projected screen with the “Warning” word blinking.

Press the [EXIT] button to clear the display.

However, the same “Warning” and “Lamp replacement” messages will be displayed again after 1 hour.

When the unit is switched to the standby mode or turned off after the lamp usage time exceeds 2000 hours, it cannot be switched back to the projection mode again. In this case, replace with a new lamp (lamp unit) and reset the lamp time (Page 30).

When the lamp usage time exceeds 2010 hours

The unit quits the projection mode (operating mode) and switches into the cool down mode.

The [LAMP] and [OPERATE] indicators will start blinking.

The projection mode (operating mode) cannot be restored until a new lamp (lamp unit) is replaced and the lamp time reset

(Page 30).

About Lamp Replacement

If this unit is installed in a constricted place, attempting to replace the lamp in that place may cause injury. Move this unit to a place large enough to perform the work.

Use only genuine replacement parts for the lamp unit. Otherwise, malfunction may occur. Also, never attempt to re-use an old lamp unit. This may cause marked performance deterioration or lamp blowout, thus leading to unit malfunction. Broken pieces of the lamp outside this unit may also cause injuries during lamp unit exchange.

Do not replace the lamp immediately after this unit has been used. The temperature of the lamp unit is still high and this may cause a burn. Allow a cooling period of 1 hour or more before replacement.

Before replacing the lamp unit, pull out the power plug from the outlet while the [STAND BY] indicator is still on. Replacing a lamp with the plug connected to the outlet may cause injuries or electric shocks.

Procedure for Lamp Replacement

Note: See manual insert for instruction with removing metal body to access bulb.

1 Loosen the screws and remove the lamp cover

Loosen the 2 screws with a screwdriver.

28

Page 28
Image 28
Meridian Audio DILA1080pHD warranty Replacing the Lamp, Light-source Lamp and Lamp Usage Time, About Lamp Replacement