Terminal Description (continued)
RS-232C External Control
Control of this unit via a computer is possible by connecting the computer to this unit with a
1. Communication Specifications
Communication specification for this unit are as follows:
Baud Rate | 9600/19200 bps |
|
|
Data Length | 8 bit |
|
|
Parity | None |
|
|
Stop Bit | 1 bit |
|
|
Flow Control | None |
|
|
2. Command Format
When sending a control command to this unit, use the following data format:
Header ID SP Command
[
SP Parameter
[
CR
Header | : Designates the head of data and the data type. | ||||||||
|
|
|
|
|
|
|
|
| |
|
|
| ! (21h): Assigns command to the projector |
|
|
|
|
| |
|
|
| ? (3Fh): Query to the projector (Asking command) |
| |||||
ID | :1: Identification number of the projector (Factory | setting is 1) | |||||||
| SP | : Designates the delimiter for ID, Command and Parameter. | (20h) | ||||||
CR | : Designates the terminal of the data. (0Dh) |
| |||||||
| *[ | ] is not necessary for Asking command. |
|
Upon executing a control command it has received, this unit sends back the following response data to the com- puter:
Header |
| ID |
| SP |
| Normal Termination Status |
|
|
|
|
|
|
|
[
SP Parameter
[
CR
Header | : Designates the head of the data. | |||||||
|
|
| @ (40h): Fetches data from the | projector | ||||
ID |
|
|
|
| ||||
: | 1: Identification number of the projector | (Factory setting is 1) | ||||||
| SP | : Designates the delimiter for ID, Command and Parameter. | (20h) | |||||
Normal Termination Status : 0 (30h) |
| |||||||
CR | : Designates the terminal of the data. (0Dh) |
|
The following 3 types of parameters are used for command and response data: 1 Numeric value 2 ON/OFF 3 Special parameters
Each parameter is as follows:
1Numeric value
A
2ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character | Hex | Meaning |
0 | 30 | OFF |
|
|
|
1 | 31 | ON |
|
|
|
36