GALILEO 616 USER GUIDE
49
while turning will scroll more quickly through the frequencies. Turning the Green knob will
zoom the location of the cursor both horizontally and vertically; press the knob while turn-
ing to zoom more quickly.
NOTE: When All EQ is bypassed, the individual fields for Parametric, TruShap-
ing, and High/Low Pass will also be shown as bypassed. These settings will
remain locked in the bypassed condition until All EQ is again enabled.
Label: Pressing the Enter button will open the naming utility; create the desired label and
press the Menu button to accept.
Mute: Highlight this field and press the Enter button or press/turn the Blue knob to toggle
between mute and unmute for the channel; when muted, the word “mute” is highlighted.
Gain: Highlight the field, and use the Red knob to adjust gain in the range of –60 dB to
+10 dB (nominally at 0 dB); pressing the knob and turning will scroll through the gain val-
ues more quickly.
Delay: Highlight the field, and turn the Red knob clockwise to adjust the delay from the
nominal zero point, and counterclockwise to reduce the value if it is above zero. Press the
knob and turn for a coarser adjustment, and to reach higher values more quickly.
Delay Units: To change the delay units, highlight and toggle through the choices with the
Enter button or press/turn the Blue knob. The Blue knob scrolls from milliseconds counter-
clockwise to samples clockwise.
Polarity: Press the Enter button or press/turn the Blue knob to go between Normal and
Reversed polarity.
SIM 3 Trim: The SIM 3 Trim field is enabled or disabled in the SIM 3 settings page,
accessed via System Settings. When an analyzer is connected, use the Red knob to adjust
the gain to the analyzer.
Link Group: Shows if the output channel is part of a Link Group; the default label is
“none”, and if part of a group its label is displayed.
NOTE: A channel can only be made part of a group using the Link Group page,
and if the Enter button is pressed a message saying this comes on the screen;
press the Cancel button to return to the Output Processing page.