MGE UPS Systems EX 5RT, EX 11RT, EX 7RT user manual EX 5/7/11 RT System, Certification Standards

Models: EX 7RT EX 11RT EX 5RT

1 72
Download 72 pages 54.19 Kb
Page 2
Image 2

EX 5/7/11 RT System

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS – This manual contains important instructions for MGE UPS SYSTEMS, INC. products that must be followed during operation and maintenance of the equipment.

WARNING

Opening enclosures expose hazardous voltages. Always refer service to

 

qualified personnel only.

ATTENTION

 

L'ouverture des cabinets expose des tensions dangereuses. Assurez-vous toujours

 

 

que le service ne soit fait que par des personnes qualifiees.

WARNUNG!

 

Das öffnen der Gehäuse legen gefährliche Spannungen bloss. Service sollte immer

 

 

nur von qualifizierten Personal durchgeführt werden.

 

 

 

WARNING

 

As standards, specifications, and designs are subject to change, please ask for con-

 

 

firmation of the information given in this publication.

ATTENTION

 

Comme les normes, spécifications et produits peuvent changer, veuillez demander

 

 

confirmation des informations contenues dans cette publication.

WARNUNG!

 

Normen, Spezifizierungen und Pläne unterliegen Anderungen. Bitte verlangen Sie

 

 

eine Bestätigung über alle Informationen, die in dieser Ausgabe gemacht wurden.

 

 

 

NOTE

 

This equipment has been tested and found to comply with the limits for a Class A

 

 

digital device, pursuant to part 15 of the FCC rules. These limits are designed to pro-

 

 

vide reasonable protection against harmful interference when the equipment is

 

 

operated in a commercial environment.

 

 

This equipment generates, uses, and can radiate radio frequency energy and, if not

 

 

installed and used in accordance with the instruction manual, may cause harmful

 

 

interference to radio communications. Operation of this equipment in a residential

 

 

area is likely to cause harmful interference in which case the user will be required to

 

 

correct the interference at user's own expense.

 

 

 

Certification Standards

IEEE 587-1980/ANSI C62.41 1980 Standards for Surge Withstand Ability

FCC rules and regulations of Part 15, Subpart J, Class A

UL listed under 1778, Standards for Uninterruptible Power Supply Equipment

IEC 61000-4-2 (ESD) : level4.

IEC 61000-4-3 (Radiated field) : level 3.

IEC 61000-4-4 (EFT) : level4.

IEC 61000-4-5 (Fast transients) : level4.

IEEE-C6241 Category B (ring wave).

IEC 61000-4-6 (electromagnetic field).

IEC 61000-4-8 (conducted magnetic field).

ii

Important Safety Information and Standards

86-86000-00 A01

Page 2
Image 2
MGE UPS Systems EX 5RT, EX 11RT, EX 7RT user manual EX 5/7/11 RT System, Certification Standards

EX 7RT, EX 11RT, EX 5RT specifications

MGE UPS Systems, a prominent player in the uninterruptible power supply (UPS) sector, offers a range of high-performance models including the EX 5RT, EX 7RT, and EX 11RT. These systems are engineered to provide reliable power protection for critical applications across various segments such as IT, telecommunications, and industrial uses.

The MGE EX 5RT, EX 7RT, and EX 11RT are designed with advanced technologies to ensure continuous operation even in the event of power disturbances. One of their standout features is the double-conversion online topology. This technology guarantees that the connected equipment receives stabilized power, free from voltage sags, surges, and frequency variations. The result is a consistent output voltage that caters to sensitive electronic systems.

These UPS systems are equipped with a wide input voltage range, allowing them to function effectively in environments with fluctuating power quality. This flexibility ensures that critical operations remain unimpeded even when the mains power supply experiences instability. Additionally, the systems have a high output power factor, which enhances efficiency and maximizes performance while reducing energy consumption.

Scalability is another key characteristic of the EX series. These models can be easily expanded and configured to meet growing power demands, making them suitable for both small and large applications. Integrated management software provides real-time monitoring and diagnostics, allowing users to take proactive measures to maintain system health and optimize performance.

The EX 5RT, EX 7RT, and EX 11RT also feature comprehensive battery management solutions. The systems employ intelligent charging technologies that prolong battery life and ensure dependable performance. Hot-swappable batteries simplify maintenance, enabling users to replace batteries without shutting down the entire system, thereby enhancing operational reliability.

Another notable aspect is their compact design, which allows for flexible installation in various environments. Whether rack-mounted or in a tower format, these UPS units can fit seamlessly into a range of settings. Furthermore, the units offer numerous connectivity options, including USB and serial ports, which facilitate integration with existing infrastructure.

In summary, MGE UPS Systems EX 5RT, EX 7RT, and EX 11RT provide comprehensive power protection through advanced technologies, scalable designs, and reliable performance. Their innovative features ensure that critical applications remain functional and secure, making them an ideal choice for organizations looking to safeguard their electronic investments.