SECTION 2
INSTALLATION
JOINING THE OVEN BODIES
For TANDEM and DOUBLE TANDEM installations, perform
Steps
For TRI TANDEM installations, perform Steps
For QUAD TANDEM installations, perform Steps
1.Determine the proper position of the ovens by referring to Figure
NOTE: The Sealing Gasket Assembly is shown attached to the left oven in Figure
LEFT OVEN | Alignment |
| |
| plate |
Slot for
alignment
plate
Sealing gasket assembly (pre- mounted)
RIGHT OVEN
2.Remove the rear axial cooling fans that are adjacent to the mating sides of the ovens, as shown in the diagram. Leave the fan wiring connected to the oven.
Figure
Oven Positioning and Alignment
Mating surface of
ovens (shown
from lower rear)
Wiring is still
connected
Figure