Ventilation

Installation

It can also be combined with other Miele built-in appliances. If the coffee machine is to be built in above another appliance, there must be a full-width, closed shelf between them.

Ventilation

Ensure that the back of the coffee machine is sufficiently ventilated, so that steam and warm air can dissipate freely.

Otherwise condensation can build up and damage the machine or the housing unit.

Installation

Before installation make sure that there is no power supply to the machine. This also applies should it ever need to be taken out of its housing unit.

The machine may only be used when it has been built in. It can only be used in ambient temperatures of +15 °C to +38 °C .

You will need two allen keys (size 3 and 5) for installing the machine.

Tip: It is useful to have somewhere at the height of the niche to place the machine on. This makes electrical connection easier.

^Using the large allen key, unscrew all four feet underneath the machine out by approx. 2 mm.

The feet can be unscrewed by up to approx. 10 mm.

If the furniture unit walls are 19 mm thick you will need to drill four holes in the sides for securing the machine.

To mark the position of these holes:

^Align the machine in the niche. Screw the side socket screws inside the machine in a little so that they make indents in the side walls, and then unscrew them again.

^Take the machine out of the niche and drill ø 4.5 mm holes,

approx. 2 mm deep where you made the indentations.