Electrical connection

Electrical connection

,All electrical work must be performed by a qualified person in accordance with local and national safety regulations.

The machine comes equipped for connection to a 208 V, 60 Hz, 3 phase power supply. It is equipped with a 6 ft. long, 12/4 AWG power cord, without a plug. A plug, rated for the required power which will fit the receptacle, is to be supplied by the electrician doing the installation. It should be connected to the main power supply.

Voltage:

208 V, 3 phase

Frequency:

60 Hz

Rated Load:

6 kW

Circuit breaker:

3 x 20 A

Black : connect to L1 (hot)

Red: connect to L2 (hot)

White: connect to L3 (hot)

Green: connect to GND (ground)

It can be converted to use a single phase power supply in accordance with the conversion and wiring diagram. The cord must be changed from a 12/4 AWG to a 10/3 AWG. Contact Miele Technical Service for more information

Voltage:

208 V, 1 phase

Frequency:

60 Hz

Rated Load:

6 kW

Circuit breaker:

2 x 30 A

^Connection should be made via a suitable isolator, with an "On/Off" button easily accessible for servicing work.

^A damaged power cord must only be replaced with a genuine Miele cord by a Miele service technician.

WARNING

THIS APPLIANCE MUST BE GROUNDED