Programming special functions

Programming special functions

Every change of the factory setting should be documented in case of possible technical service. Record any changes in the field "Adjusted value___________".

1.Setting the cold water inlet from: "Nominal water intake" to "Nominal water intake + 1 l".

The amount of water taken into the machine at each intake can be increased by 1 liter to a maximum of 9.5 liters.

^Turn the program selector to "STOP".

^Turn the machine off.

^Press and hold the "Display" and "Start" buttons, at the same time turn the machine on with the "On / Off button". The displays shows the current program status "P...".

The "Fill/Drain" indicator lights.

^Press the "Extra Drying" button once. "E01" (programming level 1) is displayed.

^Turn the program selector to "China & Crystal".

Either "10" or "11" is displayed. "10" = Nominal water intake

"11" = Nominal water intake + 1 liter

^Press "Display" to change from "10" to "11" or vice versa.

^Press the "Start" button. "SP" is displayed.

^Press the "Start" button again. The change has been saved.

Value set:

2. Selecting a second interim rinse

A second interim rinse "Interim rinse II" can be programmed to improve interim rinsing in all programs (except for "Rinse" and "Rapid").

^Turn the program selector to "STOP".

^Turn the machine off.

^Press and hold the "Display" and "Start" buttons, at the same time turn the machine on with the "On / Off" button.

The display shows the current program status "P...".

The "Fill/Drain" indicator lights.

^Press the "Extra Drying" button once. "E01" (programming level 1) is displayed.

^Turn the program selector to "Rapid". "30" or "31" is displayed.

"30" = without interim rinse II "31" = with interim rinse II.

^Press "Display" to change from "30" to "31" or vice versa.

^Press the "Start" button. "SP" is displayed.

^Press the "Start" button again. The change has been saved.

Value set:

29

Page 29
Image 29